3.6 Installing/removing the cylinder lock
Cylinder lock with key
General
Device versions with a key switch are standard
fitted with a cylinder lock. If needed, the cylinder
lock can be replaced according to the following
instructions.
Profile half cylinder – dimensions in millimeters
Requirements
The cylinder lock must fulfill the following re-
quirements:
Profile half cylinder according to EN 1303 or
DIN 18252
Dimension A = 30 mm (for A=31 mm a min-
imal overhang occurs on the housing)
Adjustable lock nose
Preparing the cylinder lock
Preparing the cylinder lock
► Adjust the angle of the lock nose [S] so
that it faces up vertically when the key is
in the removal position.
Adjusting the lock nose
Adjusting the lock nose
► The adjustment of the lock nose angle
normally occurs as follows:
Use a thin object to press in the code pin
and push the lock nose into the desired
position.