4.4.4 Switch contact output [X2] (except e-series)
The switch contact output (signal contact) is a potential-free relay contact and signals a fault for the
internal contactor. If the output is used, the corresponding DIP switch setting must be selected.
Circuit diagram:
Electrical requirements:
- Safety extra-low voltage Vcc < 50V
AC
- F ≤ 0.5A current-limiting protective devices
Connection:
Connect the wires to the switch contact output (please refer to the chapter "Terminals
[X1/X2]" for details about the terminals).
DIP switch setting
DIP switch setting
The use of the switch contact output must be
activated by a DIP switch setting.
Use switch contact output:
- "Yes": DSW1.2 = ON
- "No": DSW1.2 = OFF (Default)