User manual

Further technical instructions
45 / 48
Connectors
Enable input [X1]:
Enable input for external authorization:
Connection line:
- Cross-section (min.-max): 0.08 4 mm²
- AWG (min.-max): 28 12
Potential-free switch contact output [X2]:
Safety extra-low voltage <50V
AC
50/60Hz
External current limiting to 0.5A required
Connection line:
- Cross-section (min.-max): 0.08 4 mm²
- AWG (min.-max): 28 12
Ethernet2 connection (debug) [X3]:
RJ45
Ethernet1 connection [X4]:
LSA+ terminals
RFID (optional):
MIFARE cards or tags according to ISO14443
Cylinder lock (optional):
Profile half cylinder according to EN 1303 or
DIN 18252; Length A=30mm (31mm)
Mechanical data
Dimensions (W x H x D):
240 x 495 x 163 mm (e.g. Type 2 standard socket)
Weight:
approx. 4.8 kg (depending on device version)
Environmental conditions
Operating temperature at 16A:
-25C to +50C
without direct sunlight
Operating temperature at 32A:
-25C to +40C
without direct sunlight
Temperature behaviour:
In each case of the specified operating temperature
ranges, the device supplies the charging current
continuously available.
To increase the charging availability, the charging
current setting is changed to 16A, if the tempera-
ture is inadmissible exceeded. Subsequently, the
charging process can also be switched off.
After cooling, the charging current setting is in-
creased again.
Storage temperature range:
-25
C to +80
C
Speed of temperature change:
max. 0.5
C /min
Permitted relative air humidity:
5% to 95% non-condensing
Altitude:
max. 2000 m above sea level