User manual
Installation
32/44
Only one maximum value, which is smaller or equal to the operating current according to the type
plate, can be set with the following DIP switches:
SETTING THE AMPERAGE (DSW1) (*1)
Current DIP-Switch Figure
D1.6 D1.7 D1.8
10A OFF OFF OFF
13A ON OFF OFF
16A OFF ON OFF
20A ON ON OFF
25A OFF OFF ON
32A ON OFF ON
(*1) Preset maximum charging current value for the vehicle (Control Pilot Duty Cycle).
OBTAIN IP ADDRESS VIA DHCP (NO ADDRESSING) (*2)
DSW2.1 to DSW2.4=OFF / DSW2.5=OFF / DSW2.6=OFF
The charging procedure in STANDARD mode is carried out automati-
cally by the charging station without higher-ranking control system.
The charging station attempts to obtain an IP address via DHCP server,
if needed.
This also corresponds to the basic settings for charging stations without
network connection.
(*2) Not valid for P30 x-series