28/200
Fault in the power unit (is displayed in the colors red/blue)
"blue / blue / red / red"
Error 4003 [0011]
Overcurrent detected in the vehicle:
The vehicle has not adhered to the maximum permitted
current and has been switched off – should the prob-
lem persist, have the vehicle checked at a garage.
"blue / red / blue / red"
Error 8005 [0101]
Residual current detected in the vehicle:
Check the cable, possible damage due to a storm, tem-
porarily disconnect the charging station from the mains
and start the charging process again – should the prob-
lem persist, have the vehicle checked at a garage.
Resetting an fault:
If an interruption occurs during the plugging-in or charging procedure, the charging station will attempt to au-
tomatically restart the procedure (max. 5 times).
If the charging procedure is not able to be started, this must be confirmed by properly ending the charging
procedure (see Chapter " 2 Using the charging station [23]") or possibly by restarting the charging station. If
an untraceable fault occurs repeatedly, please contact your service partner.