User manual
Installation
31/44
4.6 DIP switch settings
Changes to the DIP switch settings only become effective after a restart of the charging station! To do this,
press the [service button] for 1second or switch the power supply voltage off/on.
DIP switches…
The DIP switches are used for the addressing and con-
figuring the charging station and are located under the
connector panel cover.
[DSW1]…Configuration (DIP switch up)
[DSW2]…Addressing (DIP switch down)
DIP switch example setting…
For better explanation, the figure shows the position of
the DIP switches for the states ON and OFF.
CONTROL FUNCTIONS OF THE CHARGING STATION
Function DIP switch Figure
External enable input [X1] is used (for de-
tails, see Chapter "↪ 4.5.3 Enable input [X1]
(excluding e-series) [26]".
D1.1 ON= yes
Switch contact output [X2] is used (for de-
tails, see Chapter "↪ 4.5.4 Switch contact
output [X2] (excluding e-series) [27]".
D1.2 ON= yes
Activate SmartHome Interface via UDP (for
details see “UDP Programmers Guide”).
Only available for c-series and x-series
charging stations.
D1.3 ON= yes
en