User manual

Installation
26/44
4.5.3 Enable input [X1] (excluding e-series)
The enable input is equipped for use with a potential-free contact. Using the enable input, it is possible to
control the charging station using external components (e.g. external key switches, ripple control receiver of
the energy supplier, house control, time switches, combination lock, photovoltaic system etc.).
Circuit diagram:
Electrical requirements:
Outside of the device, a secure isolation to dangerous voltages must be ensured for this control line.
Logical function:
Enable contact State of the charging station
open BLOCKED
closed READY FOR OPERATION
Connection:
Connect the wires to the enable input (please refer to the " 4.5.5 Terminals [X1/X2] (excluding e-series)
[28]" chapter for details about the terminal).
DIP switch setting…
The use of the enable input must be activated by a DIP
switch setting.
Use enable input:
"Yes": DSW1.1 = ON
"No": DSW1.1 = OFF (Default)