LSA+® insertion tool
Original KRONE insertion tool with solder-free and
stripping-free connection of the wires and simultaneous
trimming of the residual lengths.
Preparing the connection cable
Strip the connection cable approximately 6cm.
Fold back approx. 1cm of shielded braiding com-
pletely and wrap it with conductive adhesive textile
tape.
Connecting the cable
Fix the connecting cable at the point of the wrap-
around shielding braid in the cable clamp [K].
The cable clamp must be screwed onto the ground
point [GND] of the circuit board.
Clamp the wires to the terminal block [ETH] using
the insertion tool.
ATTENTION
Risk of damage!
● Ensure that the connection area remains clean, so that no contaminants (pieces of wire,
etc.) get inside the charging station.