User manual

Installation
30/44
LSA+® insertion tool
Original KRONE insertion tool with solder-free and
stripping-free connection of the wires and simultaneous
trimming of the residual lengths.
Preparing the connection cable
Strip the connection cable approximately 6cm.
Fold back approx. 1cm of shielded braiding com-
pletely and wrap it with conductive adhesive textile
tape.
Connecting the cable
Fix the connecting cable at the point of the wrap-
around shielding braid in the cable clamp [K].
The cable clamp must be screwed onto the ground
point [GND] of the circuit board.
Clamp the wires to the terminal block [ETH] using
the insertion tool.
ATTENTION
Risk of damage!
Ensure that the connection area remains clean, so that no contaminants (pieces of wire,
etc.) get inside the charging station.
If there is protective film present, do not remove it before the connection of the cables!