User manual

Additional technical instructions
40/44
5.5 Technical data
Electrical data
Cable feed: Surface cable routing or flush-type cable routing
Connection cross-section: Minimum cross-section (depending on the cable and
the laying system):
- 5 x 2.5 mm² (16 A nominal current)
- 5 x 6.0 mm² (32 A nominal current)
Supply terminals: Connection line:
- Solid (min.-max): 0.2 – 16 mm²
- Flexible (min.-max): 0.2 – 16 mm²
- AWG (min.-max): 24 – 6
- Flexible (min.-max) with wire end sleeve
without/with plastic sleeve:
0.25 – 10 / 0.25 – 10 mm²
Supply terminals temperature rating: 105°C
Nominal current (configurable connection values): 10 A, 13 A, 16 A, 20 A, 25 A or 32 A
3-phase or 1-phase
Mains voltage (Europe): 230 V
230/400 V 3N~ (excluding e-series)
Mains frequency: 50 Hz / 60 Hz
Network configuration: TT / TN / IT (P30 only)
Overvoltage category: III according to EN 60664
Rated short-time withstand current: < 10 kA effective value according to EN 61439-1
Fuse protection (in domestic installation): The fuse protection must be implemented according
to the locally valid regulations, according to the
socket versions / cable versions (see type plate).
DC residual-current monitoring (P30 only): FI / RDCMB ≤6mADC (integrated with correspond-
ing P30 device version)
Socket versions: Type 2 standard socket: 32 A / 400 V
AC
according to EN 62196-1 and VDE-AR-E 2623-2-2
Cable versions:
(for rating see type plate)
Type 1 cable: up to 32 A / 230 V
AC
according to EN 62196-1 and SAE-J1772
Type 2 cable: up to 32 A / 400 V
AC
according to EN 62196-1 and VDE-AR-E 2623-2-2
Protection class: I
IP protection rating for device: IP54
Protection against mechanical impact: IK08 (except for cylinder lock)