User manual

Additional technical instructions
41/44
Interfaces
Enable input [X1]: Enable input for external authorization:
Connection line:
- Cross section (min.-max): 0.08 – 4 mm²
- AWG (min.-max): 28 – 12
Potential-free switch contact output [X2]: Safety extra-low voltage <50 V
AC
50/60 Hz
External current limiting max. 0.5 A
Connection line:
- Cross section (min.-max): 0.08 – 4 mm²
- AWG (min.-max): 28 – 12
Ethernet2 connection (debug) [X3]: RJ45
Ethernet1 connection [X4]: LSA+ terminals
USB connection [X5] (P30 only): USB socket type A (max. 500 mA)
RFID (optional): MIFARE cards or tags according to ISO14443
Cylinder lock (optional): Profile half cylinder according to EN 1303 or DIN
18252
Length A=30 mm (31 mm)
Mechanical data
Dimensions (W x H x D): 240 x 495 x 163 mm (e.g. type 2 standard socket)
Weight: approx. 4.8 kg (depending on device version)
Ambient conditions
Operating temperature at 16 A: -25°C to +50°C
without direct sunlight
Operating temperature at 32 A: -25°C to +40°C
without direct sunlight
Temperature behavior: In each case, for the specified operating temperature
ranges, the device provides charging current contin-
uously.
To increase the charging availability, the charging
current specification is reduced to 16 A if the temper-
ature is exceeded. The charging procedure can also
subsequently be switched off.
After cooling down, the charging current specification
is increased again.
Storage temperature range: -25°C to +80°C
Speed of temperature change: max. 0.5°C/min
Permitted relative humidity: 5 % to 95 % (non condensing)
Altitude: max. 2000 m above sea level
en