User manual

Table Of Contents
Status LED
24/200
3 Status LED
Status LED - segments
The status LED provides information about the current
operating state of the charging station. It consists of 4
segments (S1 to S4), which can light up or flash, to-
gether or individually, in various colors.
The status LED is only visible when the power is
switched on.
If not otherwise specified, all 4 segments light up to-
gether.
Status LED Function
Flashes slowly
every 3 sec-
onds
green Ready for operation (the charging cable is not yet plugged into the vehi-
cle;
Optional: The charging station was authorized correctly by key switch or
RFID card)
Lights up con-
tinuously
green Ready for charging (charging cable is plugged in on both sides and
locked)
Flashes every
second
green Charging procedure is being performed (applies for "EN 61851 Mode 3"
charging procedure)
Lights up orange briefly after
plugging in
Wait for locking (charging cable was plugged in and the system attempts
to lock the plug)
Lights up orange for approxi-
mately 5 seconds
Self-test when plugging in and starting up the device.
Green LED goes out briefly ev-
ery 3 seconds
Wait for unplugging (charging procedure complete, vehicle unplugged)
Flashes orange slowly every 5
seconds
Temperature limit exceeded (charging procedure temporarily interrupted;
charging continues after cooling down)
Flashes red Malfunction (for details, see Chapter " 5 Troubleshooting [26]")
Segment 2 lights up orange Commissioning mode
(the charging station is in commissioning mode)