FIRE FIGHTING INSTRUCTIONS
If possible, stop the flow of gas with a remote valve. Use water spray to cool exposed containers. If fire
is extinguished and flow of gas is continues, increase ventilation to prevent a build up of a flammable /
explosive atmosphere. Extinguish sources of ignition.
.
Unusual Fire and Explosion Hazards: Be cautious of Boiling Liquid Evaporating Vapor
Explosion, if flame is impinging on surrounding containers. Direct a 500 GPM water stream onto
containers above the liquid level with remote monitors. Limit the number of personnel in proximity to the
fire. Evacuate surrounding area to at least 3000 feet in all directions.
6. ACCIDENTAL RELEASE MEASURES
Steps to be Taken in case Material is Released or Spilled
If the refrigerant is released, remove personnel from area until fumes dissipate. Provide maximum
ventilation to clear out hazardous gases. Make certain the mixture is neutral, and then collect residue
and place in a drum or other suitable container.
The preferred response is to leave the area and allow the refrigerant to dissipate. Provide maximum
ventilation. Avoid skin and eye contact or inhalation of vapors. Remove spilled liquid with absorbent and
incinerate.
Waste Disposal method
It is recommended to discharge the refrigerant to the end, handing in the abandoned refrigerant o
related department unified, dispose of the refrigerant in accordance with approved local, state, and
federal requirements. Consult state environmental protection agency and/or federal EPA.
7. HANDLING AND STORAGE
Storage: Do not place the refrigerant in sealed, unventilated areas, and near heating equipment and
nor expose to direct sunlight for long periods. Elevated temperatures can result in the
refrigerant to explosion;
The warehouse must be equipped with lightning protection equipment.
The ventilation system shall be provided with a grounding device for conducting static
elimination.
The use of explosion-proof lighting, ventilation.
Prohibit the use of equipment and tools that generate sparks.
Storage area should be equipped with leakage emergency treatment
equipment Store in normal place (temperature: -20-30C, humidity: 40-80%).
Handing: Operators should be specially trained to strictly abide by the operating rules;
Operation Disposal should be carried out in locations with local ventilation or full ventilation.
Avoid eye and skin contact and avoid inhalation for individual protection measures.
Keep away from fire, heat, smoking in the workplace.
Use explosion-proof ventilation systems and equipment.
Filling should be controlled flow rate, and a grounding device to prevent the accumulation of