Installation Manual

mkiv 5 Issue 1
KH1254
Chapter 2
All dimensions in millimetres.
TurningMech Weight : 30kg
Antenna (2.4m) Weight: 21kg
o
o
o
Power Consumption : 150VA
Operating Temperature : -25 C to +55 C
Relative Humidity 95% : +40 C
OPERATING TEMPERATURE RANGE
COMPASS SAFE DISTANCES :-
Standard Compass 3m (Grade I)
Steering Compass 1.8m (Grade II)
KELVIN HUGHES
OFF
ON
FWD
ARM
In transit MonitorArm is stowed inside
Turning Mechanism carton
PTFE WINDOW FITTED AT THIS CONNECTION
EARTHING POINT
(TORQUE LOADED TO 75 kg/m)
CABLE
GLANDS
WAVEGUIDE
OUTLET
SAFETY
SWITCH
OUTER HOUSING
14 mm holes (4 0 ff )
MONITOR
M12 bolts
1-2MM LESS THAN
WAVEGUIDE FLANGE
40
TURNING RADIUS 2412 or 1990
2262 or 1840
645
406
140
250
570
310
150
270
270
310
135
CD-4541
Figure 1 - Upmast X-Band Transceiver CAE-A12-20 (25kW):
Installation Dimensions