Maintenance Handbook

Table Of Contents
SBS-800 Series Operator & Planned Maintenance Handbook
Chapter 7: Local Control
KH-1601-2 Issue 6
Page 49 of 80
SharpEye
(continued)
Status 5: Times
ON Time
Number of hours the SharpEye
TM
has been
switched ON (HH:MM)
Run-time
Number of hours the system has been
transmitting (HH:MM)
Status 8: Temp
FPGA 1 temp
The current temperature of FPGA 1 (°C) in the
SharpEye™ as reported by the SharpEye™
FPGA 2 temp
The current temperature of FPGA 2 (°C) in the
SharpEye™ as reported by the SharpEye™
Status 11: Skew
xxx.xx°
Displays the configured Skew value configured.
(For SBS-800-3 systems this will include Squint
& Skew).
Mute Secs
Mute Sector 1
Shows the status for each Mute sector
(enabled/disabled).
Mute Sector 2
Mute Sector 3
Mute Sector 4
7.2.3.4 Network
Status Menu
Status
Radar
Control
Status
SharpEye
Network
NTP
Status
Comms
status
MISM
status
Software
Info
Exit
The IP addresses and network status can be viewed but not adjusted.
Temp
The current temperature of the MISM 5 network card in °C.
RDU Master IP
Address of the equipment Mastered (controlled) by the RDU LAN
control (normally the Remote display).
S/E Master IP
Address of the equipment Mastered (controlled) by the SharpEye
LAN control (normally the MISM-5 address).
SharpEye IP
Address of the SharpEye.
RDU IP Addr
Address of the LAN card (MISM-5).
Control Port
UDP Control Port number.
Gateway Addr
Status of the Gateway.
Netmask Addr
‘Mask’ of the IP address values e.g. 255 rejects messages from any
other network; 0 (zero) permits any other value.
Video IN MC
SharpEye™ video multi-cast address to receive video.
Source Port
SharpEye™ video source port address.
Status IN MC
Status of the multi-cast address set for the MISM-5 LAN card to accept
the SharpEye status (e.g. 239.000.000.016).
Status OUT MC
Status of the multi-cast address for the LAN MISM-5 card.
Status Port
Status of the port address for the LAN MISM-5 card.
MAC address
MAC address of the MISM-5 LAN card.
Exit