Specification

3
PHYSICALANDELECTRICALSPECIFICATIONS/OUTDOORUNITS
13SEER—HighEfciency—SinglePhase
ACCESSORIES-CondensingUnit
StartAssistKit-912933
Provides additional starting torque for the compressor
motor when operating with low line voltage or high oper-
ating temperatures.
ExtremeWindConditionMountingKit-920900
(1) Operating Voltage Range: 187v min. — 253v max.
(2) HACR Type Circuit Breakers may be used.
(3) Requires 7/8" to 3/4" reducer from line to unit.
(4) Requires 7/8" to 1-1/8" reducer from line to unit.
(5) Additional charge for line sets above 15 feet.
Values based on suction line as follows with 3/8" liquid line.
a) 3/4" = 0.6 oz. per additional foot.
b) 7/8" = 0.7 oz. per additional foot.
c) 1 1/8 = 0.8 oz per additional foot.
ModelNumberJS4BD 018KB 024KB 030KB 036KB 042KB 048KB 060KB
Electrical
Data
Volts-Cycles-Phase (1) 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1
Total Amps 9.3 13.5 14.8 18.0 19.4 23.2 27.8
Delay Fuse Max. (2) 20 25 30 35 40 50 60
Min. Circuit Ampacity 11.6 16.7 18.3 22.2 23.9 28.7 34.4
Component
Data
Coil
Area 8.3 8.3 10.0 10.0 15.3 15.3 17.9
Rows-FPI 1-18 1-18 1-18 1-18 1-18 1-18 1-18
Tube Dia Micro-ChannelMicro-ChannelMicro-ChannelMicro-ChannelMicro-ChannelMicro-Channel Micro-Channel
Fan Motor
Type PSC PSC PSC PSC PSC PSC PSC
Amps 0.35 0.7 0.7 1.4 1.5 1.5 1.5
HP 0.05 0.1 0.1 0.25 0.25 0.25 0.25
Fan Blade
Dia - # Blades 18” - 3 18” - 3 18” - 3 18” - 4 24” - 2 24” - 2 24” - 2
SCFM 2600 2800 3000 3000 3500 3500 3800
Compressor
Data
RLA 9.0 12.8 14.1 16.6 17.9 21.8 26.4
LRA 48.0 58.3 73.0 79.0 112.0 117.0 134.0
Refrigerant suction line O.D.
NOTE: Liquid line is 3/8” O.D.
for entire length.
0-24 ft. 3/4” 3/4” 3/4” 3/4” 7/8” 7/8” 7/8”
25-39 ft. 3/4” 3/4” 3/4” 7/8” (3) 7/8” 7/8” 1-1/8” (4)
40-75 ft. 3/4” 3/4” 3/4” 7/8” (3) 7/8” 7/8” 1-1/8” (4)
Approximate Weight (lbs.)
Net 109 125 138 140 179 179 188
Ship 114 130 144 146 187 187 197
Sound Rating db 72 72 72 75 79 79 79