Specification

3
PHYSICALANDELECTRICALSPECIFICATIONS/OUTDOORUNITS
14SEER—HighEfciency—SinglePhase
ACCESSORIES-CondensingUnit
StartAssistKit-912933
Provides additional starting torque for the compressor
motor when operating with low line voltage or high oper-
ating temperatures.
ModelNumberJS4BE 018KA 024KA 030KA 036KA 042KA 048KA 060KA
Electrical
Data
Volts-Cycles-Phase (1) 208/230-60-1
Total Amps 9.9 14.4 15.0 15.1 19.4 21.3 29.0
Delay Fuse Max. (2) 20 30 30 30 40 45 60
Min. Circuit Ampacity 12.1 17.7 18.5 18.6 23.9 26.3 35.6
Component
Data
Coil
Area 10.0 11.7 15.2 20.3 22.8 22.8 25.4
Rows-FPI 1-23 1-23 1-18 1-18 1-18 1-18 1-23
Tube Dia MC
Fan Motor
Type PSC BLDC
Amps 0.9 0.9 0.9 1.0 1.5 1.5 2.6
HP 0.13 0.13 0.13 0.20 0.25 0.25 0.33
Compressor
Data
RLA 9.0 13.4 14.1 14.1 17.9 19.8 26.4
LRA 48.0 58.3 73.0 77.0 112.0 109.0 134.0
Refrigerant suction line O.D.
NOTE: Liquid line is 3/8” O.D. for
entire length.
0-24 ft. 3/4” 3/4” 3/4” 3/4” 7/8” 7/8” 7/8”
25-39 ft. 3/4” 3/4” 3/4” 7/8” (3) 7/8” 7/8” 1-1/8” (4)
40-75 ft. 3/4” 3/4” 3/4” 7/8” (3) 7/8” 7/8” 1-1/8” (4)
Refrigerant charge
in ounces for outdoor unit & 15’ lineset
39.0 45.0 51.0 62.0 75.0 101.0 81.0
Approximate Weight (lbs.)
Net 107 127 132 146 175 177 187
Ship 113 134 140 155 184 186 196
Sound Rating db 74 74 75 78 78 78 78