Installation Guide

3
IMpORTANT SAFETY INFORMATION
INSTALLER: Please read all instructions before servicing
this equipment. Pay attention to all safety warnings and
any other special notes highlighted in the manual. Safety
markings are used frequently throughout this manual to
designate a degree or level of seriousness and should
not be ignored.
wARNING - indicates a potentially hazardous situation
that if not avoided, could result in personal injury or death.
CAUTION - indicates a potentially hazardous situation
that if not avoided, may result in minor or moderate injury
or property damage.
wARNING:
The safety information listed in this manual
must be followed during the installation,
service,andoperationofthisunit.Unqualied
individualsshouldnotattempttointerpretthese
instructionsorinstallthisequipment.Failure
tofollowsafetyrecommendationscouldresult
inpossibledamagetotheequipment,serious
personalinjuryordeath.
wARNING:
Improper installation, service, adjustment,
or maintenance may cause explosion, re,
electricalshockorotherhazardousconditions
whichmayresultinpersonalinjuryorproperty
damage. Unless otherwise noted in these
instructions, only factory authorized kits or
accessoriesmaybeusedwiththisproduct.
wARNING:
Unlessotherwisenotedintheseinstructions,
onlyfactoryauthorizedkitsoraccessoriesmay
beusedwithorwhenmodifyingthisproduct.
wARNING:
Donotinstallthisfurnaceifanyparthasbeen
submerged under water. A ood damaged
furnaceis extremelydangerous. Attempts to
usethefurnacemayresultinreorexplosion.A
qualiedserviceagencyshouldbecontactedto
inspectthefurnaceandtoreplaceanyelectrical
orcontrolsystempartsthathavebeenwetor
underwater.
• Tominimizeequipmentfailureorpersonalinjury,itis
essential that only qualified individuals install, service, or
maintain this equipment. If you do not posses mechanical
skills or tools, call your local dealer for assistance.
• Follow all precautions in the literature, on tags, and
on labels provided with the equipment. Read and
thoroughly understand the instructions provided with
the equipment prior to performing the installation and
operational checkout of the equipment.
• Usecautionwhenhandlingthisapplianceorremoving
components. Personal injury can occur from sharp metal
edges present in all sheet metal constructed equipment.
• Donotstoreanyofthefollowingon,orincontactwith,
the unit: Rags, brooms, vacuum cleaners, or other
cleaning tools, spray or aerosol cans, soap powders,
bleaches, waxes, cleaning compounds, plastics or
plastic containers, paper bags or other paper products,
gasoline, kerosene, cigarette lighter fluid, dry cleaning
fluids, paint thinners, or other volatile fluids.
• Theinstallershouldbecomefamiliarwiththeunitswiring
diagram before making any electrical connections to the
unit. See the unit wiring label or Figure 19 (page 30).
• Alwaysreinstallthedoorsontheindoorblowerafter
servicing or cleaning/changing the filters. Do not operate
the indoor blower without all doors and covers in place.
REQUIREMENTS & CODES
• This furnace must be installed in accordance with
these instructions, all applicable local building codes
and the current revision of the National Fuel Gas Code
(NFPA54/ANSI Z223.1) or the Natural Gas and Propane
Installation Code, CAN/CGA B149.1.
• Useonlywithtypeofgasapprovedfor thisfurnace.
Refer to the furnace rating plate.
• Installthisfurnaceonlyinalocationandpositionas
specified on page 5.
• Provideadequatecombustionandventilationairtothe
furnace space as specified on pages 6 - 10.
• Combustion products must be discharged outdoors.
Connect this furnace to an approved vent system only,
as specified on pages 9 - 10.
• Never test for gas leaks with an open ame. Use
a commercially available soap solution to check all
connections. See pages 16 - 17.
• Thisfurnaceisdesignedtooperatewithamaximum
external pressure rise of 0.5 inches of water column.
Consult Tables 3 & 4 (pages 27 - 29), and the rating
plate for the proper circulating air flow and temperature
rise. It is important that the duct system be designed to
handle the desired flow rate and temperature rise. An
improperly designed duct system can result in nuisance
shutdowns, and comfort or noise issues.
• Whensupplyductscarryaircirculatedbythefurnace
to areas outside the space containing the furnace, the
return air shall also be handled by duct(s) sealed to
the furnace casing and terminating outside the space
containing the furnace. See pages 11 - 12.
• This furnace may be used for temporary heating of
buildings or structures under construction. See the
guidelines listed on page 5.