Inverter Air Conditioner User Manual KSV25HRH, KSV35HRH, KSV50HRH, KSV71HRH, KSV90HRH, KSD25HRH, KSD35HRH, KSD50HRH, KSD71HRH, KSD90HRH
Congratulations Contents Congratulations and thank you for choosing our Inverter split system room air conditioner. We are sure you will find your new air conditioner a pleasure to use. Before you use the air conditioner, we recommend that you read through the entire user manual, which provides the description of the air conditioner and its functions.
Safety instructions Meanings of symbols used in this manual are shown below: WARNING warning This symbol indicates information concerning your personal safety or information on how to avoid damaging the air conditioner TIPS & INFORMATION important This symbol indicates tips and information about use of the appliance environmentTIPS ENVIRONMENTAL This symbol indicates tips and information about economical and ecological use of the appliance TIPS & INFORMATION important • Contact an authorised installer
Safety instructions WARNING warning • Do not place obstacles around air inlets or inside of air outlet. It may cause failure of appliance or accident. • Turn off at the main power switch if the unit will not be used for a long period of time. It may cause failure of the unit or fire. • Do not use strong chemical cleaners such as detergents, abrasive cleaners or thinners, as they may damage the appliance causing scratches, discolouration or deteriorate the surface finish. Use a soft cloth for cleaning.
Installation drawing Fig. 1 3 4 Installation plate ST3.9x25(5) ng screw 15cm or more 1 12cm or more 12cm or more 5 Remote control Air ter 200cm or more Additional drain pipe Before screwing the remote controller holder to the wall, make sure that control signals are properly received by indoor unit.
Remote control specifications Rated voltage 3.0V (2x 1.5V AAA) Signal receiving range 8m Using the remote control Mo de ON /O FF Fan /qui et Ti m er LED Tur bo Sw Fol me low Sh cutort Dir ing ect Sel cle f an Location of the remote controller • Use the remote controller within a distance of 8 meters from the appliance, pointing it towards the receiver. Reception is confirmed by a beep.
Indoor unit display Digital display • Displays the temperature settings when the air conditioner is operational. Replacing batteries • Displays the room temperature in FAN mode. The following cases signify exhausted batteries. Replace old batteries with new ones. • Displays the self-diagnostic codes. • Displays ' ' for three seconds when Timer ON, Swing, Turbo or Quiet feature is activated. • Displays ' The remote controller is powered by two dry batteries (2x AAA 1.
Operation of buttons 1. ON/OFF Button This button turns the air conditioner ON and OFF. 2. Mode Button Press this button to modify the air conditioner mode in a sequence of following: AUTO > COOL > DRY > HEAT > FAN NOTE: Please do not select HEAT mode if the machine you purchased is cooling only type. Heat mode is not supported by the cooling only appliance. 3. Timer Button Press this button to initiate the auto-on/off time sequence.
Operation of buttons 8. UP Button ( + ) Push this button to increase the indoor temperature setting in 1°C increments to 30°C. DOWN Button ( - ) Push this button to decrease the indoor temperature setting in 1°C increments to 17°C. 9. Fan/quiet Button • Used to select the fan speed in four steps: AUTO > LOW > MED > HIGH NOTE: You can not switch the fan speed in AUTO or DRY mode. • Press the button for more than 2s to activate the Quiet function.
Indicators on LCD Information are displayed when the remote controller is powered up.
How to use the buttons NOTE: In the FAN mode, the setting temperature is not displayed in the remote controller and you are not able to control the room temperature either. In this case, only step 1, 3 and 4 may be performed. 3 1 Mode ON/OFF Fan Quiet Timer Sleep Swing LED Follow me Direct Turbo Short cut Self clean 2 1 Mode ON/OFF Fan Quiet 2 3 Auto operation Ensure the unit is plugged in and power is available.
Timer operation WARNING caution Mode ON/OFF 1 Ti m e r Sleep Swing LED Follow me Direct Turbo Short cut Self clean To set the Auto-ON time 1. Press the Timer button till the remote controller shows Timer On indicator “ ”, the last Auto-on setting time and the signal "h" will be shown on the LCD display area. Now it is ready to reset the Auto-on time to START the operation. 2. Push the UP and Down button to set desired Auto-on time.
Examples of timer operation Timer on (Auto-on Operation) Combined timer (Setting both ON and OFF timers simultaneously) Timer off/Timer on (On/Stop/Start operation) Off Set Start 6 hours later On The Timer On feature is useful when you want the unit to turn on automatically before you return home. The air conditioner will automatically start operating at the set time. Example To start the air conditioner in 6 hours. 1.
Special functions SLEEP operation SELF CLEAN function SLEEP operation • Airborne bacteria use the moisture on the indoor heat exchanger to grow. Regular drying of the exchanger prevents this growth. By simply pressing the SELF CLEAN button, the system will automatically manage the process. This cleaning action may be done as frequently as desired. • For cooling models, only the indoor fan is active in low speed for 30 minutes and the unit turns off automatically.
Airflow directional control The direction of airflow can be adjusted for maximum comfort. WARNING caution • Do not operate the air conditioner for long periods with the air flow direction set downward in cooling or dehumidifying mode. Otherwise, condensation may occur on the surface of the horizontal louver causing moisture to drop on to the floor or on furnishings. • After a quick restart, the horizontal louver may remain static for approximately 10 seconds.
Operating temperature Manual operation Mode Temperature Cooling operation Heating operation Room temperature 17°C – 32°C 0°C – 30°C Outdoor temperature 0°C – 50°C -15°C – 30°C The Air conditioner temperature can be set between the range of 17°C to 30°C. caution • This switch is used for testing purposes only. Please do not use it unless necessary. • To restore the remote controller operation, use the remote controller directly. NOTE: 1.
Care and maintenance Before maintenance • Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. NOTE: Power supply must be disconnected before attempting to clean or service. WARNING warning Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
Care and maintenance 5. After the filters are dry, refit the small filters onto the large air filter. 6. Re-insert the filters back into the unit following the reverse order as described in steps 1 & 2. 7. Close the front panel. Make sure the buckles are fully fit and the panel is completely closed. Preparation for extended non-operation If you plan not to use unit for a long time, perform the following: 1. Clean the indoor unit and filters. Panel buckles 2.
Troubleshooting Troubleshooting tips The following events may occur during normal operation, and may not indicate malfunction Symptom Cause Operation is delayed after restart To prevent blowout of the fuse, the compressor will not operate while the protection circuit is working for about 3 minutes after sudden OFF/ON operation of the power supply, this is normal operation and designed to protect the compressor.
Troubleshooting Before you call for or request servicing, troubleshoot a problem by performing following checks: Symptom Diagnostic Is there a power failure? Has a switch been turned off, a circuit breaker tripped or a fuse blown? Unit will not operate Is the timer operating? Are the batteries used in the remote controller exhausted? Are the batteries used in the remote controller loaded properly? Are the air Is a ers dirty? unrestricted in & out of indoor & outdoor units? Are the temperature and mode
Notes Notes 21
Notes 22 Notes
Warranty 23
For more information on all Kelvinator appliances, or for dimension and installation information, call into your retailer, phone or email our customer care team or visit our website: AUSTRALIA phone: 1300 363 640 fax: 1800 350 067 email: customercare@electrolux.com.au web: kelvinator.com.au NEW ZEALAND phone: 0800 436 245 fax: 0800 225 088 email: customercare@electrolux.co.nz web: kelvinator.co.nz Kelvinator. We are part of the Electrolux Family.