Datasheet

4© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com A4031_ALS30_31 • 3/24/2017
Screw Terminal Aluminum Electrolytic Capacitors – ALS30/31 Series, +85°C
Termination Tables
Code
A C G
Termination
Code
Thread
Termination
Style
T DT Thread Depth (TD) Z
±0.5 ±0.5 Minimum Nominal
Standard Termination Option
A (D = 36) M5 Round 7.14 8 10
A (D > 36) M5 Oval 5.5 13 10 10
Other Termination Options
C M6 Round 5.5 13 10
G
M6 Round 6.35 17 11.8
Dimensions in mm
L
SIDE VIEW OVAL
Termination Codes:
A
D
Optional Mounting
Stud (M x H)
+
DT
V
Safety Vent
TD
Polarity
Mark
ROUND
Termination Codes:
A (D = 1.375), C, G
LT
S
T
(From Deck)
+
DT
V
Safety Vent
Polarity
Mark
Z
TD
Case Polarity
Due to the presence of electrolyte in the capacitor, the aluminum can and stud mounting will essentially be at the same
polarity as the negative terminal. We recommend that the stud and can be insulated (see accessories for insulating nuts).
Terminations
Aluminum inserts with M5 threads as standard, maximum torque 2NM. Optional M6 threaded inserts have a maximum
torque 4NM. Maximum torque for stud mounting M8:4NM and M12:8NM.