Datasheet

© KEMET Electronics Corporation, P.O. Box 5928, Greenville, S.C. 29606, (864) 963-6300 27
CERAMIC MOLDED AXIAL & RADIAL
PERFORMANCE CHARACTERISTICS
Ceramic Molded
Axial/Radial - Standard
GENERAL SPECIFICATIONS
Working Voltage:
C0G – 50, 100, 200
X7R 50, 100, 200
Temperature Characteristics:
C0G 0 ±30 PPM / °C from -55°C to +12C
X7R ± 15% from -55°C to +12C
Capacitance Tolerance:
C0G ±0.5pF, ±1%, ±2%, ±5%, ±10%, ±20%
(±0.5pF is tightest tolerance available)
X7R ±10%, ±20%, -0 +100%, +80% / -20%
Construction:
Monolithic block of ceramic dielectric with
Interdigitated internal electrodes, encapsulated
in a molded case, and having axial or radial leads.
Meets flame test requirements of UL Standard 94V-0.
Lead Material:
Axial: Solder coated copper clad steel
Radial: Solder-coated copper standard (100% tin
plated optional)
Solderability:
MIL-STD-202, Method 208, Sn62 solder, 24C for
5 ±1/2 seconds.
Terminal Strength:
EIA-198 Method 303, Condition A (2.2 kg)
ELECTRICAL
Capacitance:
Within specified tolerance and when measured with
1 volt rms at 1kHz (1000 pF or less at 1 MHz for C0G).
Dissipation Factor @25°C:
25°C at 1kHz (1000 pF or less at 1 MHz for C0G).
C0G 0.15% maximum
X7R 2.5% maximum
Insulation Resistance:
After 2 minutes electrification at 25°C and rated voltage
C0G 100K M
or 1000 M F, whichever is less.
X7R 100K M
or 1000 M F, whichever is less.
Dielectric Withstanding Voltage:
250% of rated voltage for 5 seconds with current limited
to 50 mA at 25°C.
MIL-STD-202, Method 208, Sn62 solder, 245 C for
5 ±1/2 seconds.
Terminal Strength:
EIA-198 Method 303, Condition A (2.2 kg)
ELECTRICAL
Capacitance:
Within specified tolerance and when measured with
1 volt rms at 1kHz (1000 pF or less at 1 MHz for C0G).
Dissipation Factor @25°C:
25°C at 1kHz (1000 pF or less at 1 MHz for C0G).
C0G – 0.15% maximum
X7R – 2.5% maximum
Insulation Resistance:
After 2 minutes electrification at 25°C and rated voltage
C0G – 100K M
or 1000 M F, whichever is less.
X7R 100K M
or 1000 M F, whichever is less.
Dielectric Withstanding Voltage:
250% of rated voltage for 5 seconds with current limited
to 50 mA at 25°C.