Datasheet

4© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4049_EDH • 4/23/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Surface Mount Aluminum Electrolytic Capacitors – EDH, +105°C
Compensation Factor of Ripple Current (RC) vs. Frequency
Frequency 60 Hz 120 Hz 1 kHz 10 kHz
Coecient 0.85 1.00 1.15 1.25
Test Method & Performance
Conditions Load Life Test Shelf Life Test
Temperature 105°C 105°C
Test Duration 2,000hours 1,000hours
Ripple Current Maximumripplecurrentspeciedat120Hz105°C No ripple current applied
Voltage
ThesumofDCvoltageandthepeakACvoltage
mustnotexceedtheratedvoltageofthecapacitor
No voltage applied
Performance The following specications will be satised when the capacitor is restored to 20°C:
CapacitanceChange
CanØ=4–6.3mmwithin±25%oftheinitialvalue CanØ=8–16mmwithin±20%oftheinitialvalue
Dissipation Factor Doesnotexceed200%ofthespeciedvalue
Leakage Current Doesnotexceedspeciedvalue
Shelf Life
Thecapacitance,ESRandimpedanceofacapacitorwillnotchangesignicantlyafterextendedstorageperiods,however,
theleakagecurrentwillveryslowlyincrease.
KEMET'sEaluminumelectrolyticcapacitorsshouldnotbestoredinhightemperaturesorwherethereisahighlevelof
humidity.ThesuitablestorageconditionforKEMET'sEaluminumelectrolyticcapacitorsis+5to+35°Candlessthan75%
inrelativehumidity.KEMET'sEaluminumelectrolyticcapacitorsshouldnotbestoredindampconditionssuchaswater,
saltwatersprayoroilspray.KEMET'sEaluminumelectrolyticcapacitorsshouldnotbestoredinanenvironmentfullof
hazardousgas(hydrogensulphide,sulphurousacidgas,nitrousacid,chlorinegas,ammonium,etc.)KEMET'sEaluminum
electrolyticcapacitorsshouldnotbestoredunderexposuretoozone,ultravioletraysorradiation.
If a capacitor has been stored for more than 18 months under these conditions and it shows increased leakage current,
then a treatment by voltage application is recommended.
Re-Age (Reforming) Procedure
Applytheratedvoltagetothecapacitoratroomtemperatureforaperiodofonehour,oruntiltheleakagecurrenthasfallen
toasteadyvaluebelowthespeciedlimit.Duringre-agingamaximumchargingcurrentoftwicethespeciedleakage
currentor5mA,whicheverisgreater,issuggested.