Datasheet

5© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard A4006_ESC • 6/8/2020
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Radial Aluminum Electrolytic Capacitors – ESC, +105°C
Test Method & Performance
Conditions Load Life Test Shelf Life Test
Temperature
105°C
105°C
Test Duration
CanØ≥5x11,≤10x12.5mm
2,000 hours
1,000 hours
CanØ≥10x15mm
3,000 hours
If dimension is down size, endurance will be 1,000 hours less than standard
Ripple Current Maximumripplecurrentspeciedat100KHz105°C No ripple current applied
Voltage
ThesumofDCvoltageandthepeakACvoltagemustnotexceed
the rated voltage of the capacitor
No voltage applied
Performance The following specications will be satised when the capacitor is restored to 20°C:
Capacitance Change Within ±20% of the initial value
Dissipation Factor Doesnotexceed200%ofthespeciedvalue
Leakage Current Doesnotexceedspeciedvalue
Shelf Life
Thecapacitance,ESRandimpedanceofacapacitorwillnotchangesignicantlyafterextendedstorageperiods,however,
the leakage current will very slowly increase.
KEMET's E aluminum electrolytic capacitors should not be stored in high temperatures or where there is a high level of
humidity. The suitable storage condition for KEMET's E aluminum electrolytic capacitors is +5 to +35°C and less than 75%
in relative humidity. KEMET's E aluminum electrolytic capacitors should not be stored in damp conditions such as water,
saltwater spray or oil spray. KEMET's E aluminum electrolytic capacitors should not be stored in an environment full of
hazardous gas (hydrogen sulphide, sulphurous acid gas, nitrous acid, chlorine gas, ammonium, etc.) KEMET's E aluminum
electrolyticcapacitorsshouldnotbestoredunderexposuretoozone,ultravioletraysorradiation.
If a capacitor has been stored for more than 18 months under these conditions and it shows increased leakage current,
then a treatment by voltage application is recommended.
Re-Age (Reforming) Procedure
Apply the rated voltage to the capacitor at room temperature for a period of one hour, or until the leakage current has fallen
toasteadyvaluebelowthespeciedlimit.Duringre-agingamaximumchargingcurrentoftwicethespeciedleakage
current or 5 mA, whichever is greater, is suggested.