Datasheet

8© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com S6014_FT • 3/30/2017
Supercapacitors – FT Series
Measurement Conditions
Capacitance (Charge System)
Capacitanceiscalculatedfromexpression(9)bymeasuringthechargetimeconstant(τ)ofthecapacitor(C).Priorto
measurement, the capacitor is discharged by shorting both pins of the device for at least 30 minutes. In addition, use the polarity
indicator on the device to determine correct orientation of capacitor for charging.
Eo: 3.0 (V) Product with maximum operating voltage of 3.5 V
5.0 (V) Product with maximum operating voltage of 5.5 V
6.0 (V) Product with maximum operating voltage of 6.5 V
10.0 (V) Product with maximum operating voltage of 11 V
12.0 (V) Product with maximum operating voltage of 12 V
τ: TimefromstartofcharginguntilVcbecomes0.632Eo(V)
(seconds)
Rc: Seetablebelow(Ω).
Charge Resistor Selection Guide
Cap FA FE FS
FY
FR
FM, FME
FMR, FML
FMC
FG
FGR
FGH FT FC, FCS HV
FYD FYH FYL
0.010 F
5,000Ω
5,000Ω
5,000Ω
0.022 F
1,000Ω
1,000Ω
2,000Ω
2,000Ω
2,000Ω
2,000Ω
2,000Ω
2,000Ω
Discharge
0.033 F
Discharge
0.047 F
1,000Ω
1,000Ω
1,000Ω
2,000Ω
1,000Ω
2,000Ω
1,000Ω
2000Ω
1,000Ω
2,000Ω
0.10 F
510Ω
510Ω
510Ω
1,000Ω
510Ω
1,000Ω
1000Ω
1,000Ω
1,000Ω
Discharge
510Ω
Discharge
0.22 F 200Ω 200Ω 200Ω 510Ω 510Ω 510Ω
0H: Discharge
0V:1000Ω
1,000Ω Discharge 200Ω Discharge
0.33 F
Discharge
0.47 F
100Ω
100Ω
100Ω
200Ω
200Ω
200Ω
1,000Ω
Discharge
100Ω
Discharge
1.0 F
51Ω
51Ω
100Ω
100Ω
100Ω
100Ω
510Ω
Discharge
100Ω
Discharge
Discharge
1.4 F
200Ω
1.5 F
51Ω
510Ω
2.2 F
100Ω
200Ω
51Ω
2.7 F
Discharge
3.3 F
51Ω
4.7 F
100Ω
Discharge
5.0 F
100Ω
5.6 F
20Ω
10.0 F
Discharge
22.0 F
Discharge
50.0 F
Discharge
100.0 F
Discharge
200.0 F
Discharge
*Capacitance values according to the constant current discharge method.
*HV Series capacitance is measured by discharge system
Vc
Rc
Switch
C
+
Eo
Capacitance:
C =
τ
(F) (9)