Datasheet

RoHS
Compliant
Rated voltage 300 VAC 50/60 Hz
Capacitance range 0.01 – 10 µF
Capacitance tolerance ± 20% standard, ± 10% option
Temperature range –55 to +105°C
Climatic category 55/105/56/B
Approvals
ENEC, UL, cUL
Dissipation factor tanδ Maximum values at +23°C
C 0.1 µF 0.1µF < C 1 µF C > 1 µF
1 kHz 0.1% 0.1% 0.1%
10 kHz 0.2% 0.4% 0.8%
100 kHz 0.6%
Test voltage between The 100% screening factory test is carried out at
terminals
2200 VDC. The voltage level is selected to meet the
requirements in applicable equipment standards. All
electrical characteristics are checked after the test.
Resonance frequency Tabulated self-resonance frequencies f
0
refer to
5 mm lead length.
Insulation resistance
C 0.33 µF:
30 000 M
C > 0.33 µF: 10 000 s
In DC applications Recommended voltage 760 VDC
pHE840E
EMI suppressor, class X2, metallized polypropylene
0.01 – 10 µF, 300 VAC, +105°C
New improved design: small dimensions including low profile capacitors
tYpiCaL appLiCations ConstRuCtion
tECHniCaL data
For worldwide use as electromagnetic
interference suppressor in all X2 and
across-the-line applications.
encapsulated in self-extinguishing material
meeting the requirements of UL 94 V–0.
EnViRonmEntaL tEst data
Endurance EN/IEC 60384-14:2005 1.25 x U
R
VAC 50 Hz, once every hour
increased to 1000 VAC for 0.1 s,
1000 h at upper rated temperature
Vibration IEC 60068–2–6 3 directions at 2 hours each, No visible damage
Test Fc 10–55 Hz at 0.75 mm or 98 m/s
2
No open or short circuit
Bump IEC 60068–2–29 1000 bumps at No visible damage
Test Eb 390 m/s
2
No open or short circuit
Change of temperature IEC 60068–2–14 Upper and lower rated No visible damage
Test Na temperature 5 cycles
Active flammability EN/IEC 60384-14:2005
Passive flammability Enclosure material of
EN/IEC 60384-14:2005
UL94V–0 flammability class
Humidity IEC 60068-2-3 +40°C and 56 days
Test Ca 90 – 95% R.H.
P d std l max l b
10.0 ± 0.4 0.6 17 30 ±0.4
15.0 ± 0.4 0.8 17 30 ±0.4
22.5 ± 0.4 0.8 6 30 ±0.4
27.5 ± 0.4 0.8 6 30 ±0.4
37.5 ± 0.5 1.0 6 30 ±0.7
Tolerance in lead length
< 30 mm mm
30 mm mm
+0
–1
+5
–0
L
H
B
p
l
d
0.5
b
Not for use in series with the mains.
See www.kemet.com for more information.
Metallized polypropylene winding,

Summary of content (2 pages)