Datasheet

RoHS
Compliant
Rated voltage 275 VAC 50/60 Hz (ENEC)
280 VAC 50/60 Hz (UL, cUL)
Capacitance range 0.01 – 10.0 µF
Capacitance tolerance ± 20% standard, ± 10% option, ± 5% on request
Temperature range –55 to +105°C
Climatic category 55/105/56/B
Approvals ENEC, UL, cUL
Dissipation factor Maximum values at +23°C
C 0.1 µF 0.1µF < C 1 µF C > 1 µF
1 kHz 0.1% 0.1% 0.1%
10 kHz 0.2% 0.4% 0.8%
100 kHz 0.6%
Test voltage between The 100% screening factory test is carried out at 2200
terminals
VDC. The voltage level is selected to meet the
requirements in applicable equipment standards. All
electrical characteristics are checked after the test.
Insulation resistance C 0.33 µF: 30 000 M
C > 0.33 µF: 10 000 s
In DC applications Recommended voltage 760 VDC
pHE840m
EMI suppressor, class X2, metallized polypropylene
0.01 – 10.0 µF, 275/280 VAC, +105°C
Small dimensions including low profile capacitors
tYpiCaL appLiCations ConstRuCtion
tECHniCaL data
For worldwide use as electromagnetic
interference suppressor in all X2 and
across-the-line applications.
Metallized polypropylene film encapsulated
with selfextinguishing epoxy resin in a box
of material recognized to UL 94 V–0.
p d std l max l b
7.5 ± 0.4 0.6 17 20 ±0.4
10.0 ± 0.4 0.6 17 30 ±0.4
15.0 ± 0.4 0.8 17 30 ±0.4
22.5 ± 0.4 0.8 6 30 ±0.4
27.5 ± 0.4 0.8 6 30 ±0.4
37.5 ± 0.5 1.0 6 30 ±0.7
Tolerance in lead length
< 30 mm mm
30 mm mm
+0
–1
+5
–0
L
H
B
p
l
d
0.5
b
EnViRonmEntaL tEst data
Endurance EN/IEC 60384-14:2005 1.25 x U
R
VAC 50 Hz,
once every hour increased
to 1000 VAC for 0.1 s,
1000 h at upper rated temperature
Vibration IEC 60068–2–6 3 directions at 2 hours each, No visible damage
Test Fc 10–55 Hz at 0.75 mm or 98 m/s
2
No open or short circuit
Bump IEC 60068–2–29 1000 bumps at No visible damage
Test Eb 390 m/s
2
No open or short circuit
Change of temperature IEC 60068–2–14 Upper and lower rated No visible damage
Test Na temperature 5 cycles
Active flammability EN/IEC 60384-14:2005
Passive flammability Enclosure material of
EN/IEC 60384-14:2005
UL94V–0 flammability class
Humidity IEC 60068-2-3 +40°C and 56 days
Test Ca 90 – 95% R.H.
Not for use in series with the mains.
See www.kemet.com for more information.