Datasheet

3© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard LF0057_SN 7/23/2018
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
AC Line Filters – Normal Mode SN Coils, Standard
Environmental Compliance
All KEMET AC Line Filters are RoHS Compliant.
RoHS Compliant
Table 1 – Ratings & Part Number Reference
Part Number
Rated
Current AC
(A)
Inductance
(µH)
Minimum
DC Resistance/
Line (mΩ)
Maximum
Temperature
Rise (K)
Maximum
Wire
Diameter
(mm)
Weight
(g)
Approximate
SN3-200
1
10
0.045
15
0.8
SN5-300
2
25
0.042
18
2.6
SN5-400
2
48
0.058
22
3.0
SN8S-300
2
26
0.042
19
4.1
SN8S-400
2
46
0.052
20
4.5
SN8S-500
2
72
0.068
23
4.9
SN8D-300
2
45
0.052
20
6.1
SN8D-400
2
80
0.072
24
6.8
SN8D-500
2
125
0.100
27
7.3
SN10-300
3
40
0.035
18
10.2
SN10-400
3
72
0.042
20
10.8
SN10-500
3
110
0.052
26
11.8
SN12-400
5
64
0.032
32
15.8
SN12-500
5
100
0.040
34
18.2
SN13-300
6
51
0.023
28
31.1
SN13-400
6
92
0.030
33
35.1
SN13-500
6
143
0.036
38
38.2
SN16-300
8
60
0.021
21
39.0
SN16-400
8
108
0.027
24
44.4
SN16-500
8
168
0.031
36
51.2
Performance Characteristics
Item Performance Characteristics
Rated Current AC Range 1 – 8 A
Rated Inductance Range 10 – 168 µH minimum
Inductance Measurement Condition 100 kHz
Wire Type 1 PVF and 1 UEW and 1 PEW
Thermal Class A(105°C)
Operating Temperature Range 25°Cto+105°C(includeselftemperaturerise)