Datasheet

7© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard LF0036_SSHB10H 3/4/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
AC Line Filters – Dual Mode SSHB Coils, 10H Series, High Impedance Type
Packaging
Type Packaging Type Pieces Per Box
SSHB10H Tray 300
Handling Precautions
Precautions for product storage
AC Line Filters should be stored in normal working environments. While the chokes themselves are quite robust in other
environments,solderabilitywillbedegradedbyexposuretohightemperatures,highhumidity,corrosiveatmospheres,and
long term storage.
KEMETrecommendsthatmaximumstoragetemperaturenotexceed40°Candmaximumstoragehumiditynotexceed70%
relativehumidityandatmospheresshouldbefreeofchlorineandsulfurbearingcompounds.Temperatureuctuations
shouldbeminimizedtoavoidcondensationontheparts.Avoidalsostoragenearstrongmagneticeldsasthismight
magnetize the product.
For optimized solderability, AC Line Filters’ stock should be used promptly, preferably within 6 months of receipt.
Product temperature rise values
The values listed for temperature rise are the result of self-heating in wires when the rated current (commercial frequency)
is applied.
Check and evaluate the value of the core temperature rise under actual operating conditions when using.
Export Control
For customers in Japan
Forproductsthatarecontrolleditemssubjecttothe“ForeignExchangeandForeignTradeLaw”ofJapan,theexportlicense
speciedbythelawisrequiredforexport.
For customers outside Japan
AC Line Filters should not be used or sold for the use in the development, production, stockpiling or utilization of any
conventional weapons, mass-destruction weapons (nuclear, chemical, biological weapons or missiles) or any other
weapons.