Datasheet

2© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard T2031_T110_AXIAL_T212 10/19/2018
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
2
Tantalum Through-Hole Capacitors – Hermetically Sealed
T110 Series Axial MIL–PRF–39003 Polar Type and T212 (CSR13 Style)
Ordering Information – T110
T 110 A 105 K 050 A T 7200
Capacitor
Class
Series
Case
Size
Capacitance Code
(pF)
Capacitance
Tolerance
RatedVoltage
(VDC)
FailureRate/Military
ProductOnly
Termination
Finish
Specication
T =
Tantalum
Hermetically
sealed axial
capacitor
A
B
C
D
First two digits
represent
signicantgures.
Thirddigitspecies
numberofzeros.
J = ±5%
K = ±10%
M = ±20%
006 = 6
010 = 10
015 = 15
020 = 20
035 = 35
050 = 50
060 = 60
075 = 75
100 = 100
125 = 125
A = N/A T = 100% Tin
S = Standard
(Sn/Pb)
Blank = Sleeved/ Bulk
0100 = Without sleeve
7200=Tape&Reel
7293 & 7443 = Ammo
All capacitors are sleeved
unlessspecied.
Ordering Information – T212 (CSR13 Style)
MIL product
T 212 A 105 K 050 B S 7200
Capacitor
Class
Series
Case
Size
Capacitance Code
(pF)
RatedVoltage
(VDC)
FailureRate/Military
ProductOnly
Specication
T =
Tantalum
Hermetically
sealed axial
military
grade
capacitor
A
B
C
D
First two digits
represent
signicantgures.
Thirddigitspecies
numberofzeros.
J = ±5%
K = ±10%
M = ±20%
006 = 6
010 = 10
015 = 15
020 = 20
035 = 35
050 = 50
075 = 75
100 = 100
Graded:
B = 0.1%/k hours
C = 0.01%/k hours
D=0.001%/khours
G= 1.0 %/k hours
Exponential:
M = 1%/k hours
P=0.1%/khours
R=0.01%/khours
S = 0.001%/k hours
S =
Standard
(Sn/Pb)
All capacitors are sleeved
unlessspecied.
0100 = Without sleeve
7200=Tape&Reel
7293 & 7443 = Ammo
4250 = "A" surge current
4251 = "B" surge current
4252 = "C" surge current
Ordering Information – MIL–PRF–39003
M39003 /01 6003 A
Capacitor Class Slash DashNumber Surge Option
Military
specication
number
Specication
sheetnumber
Failure rate
level
A = C-4250
B = C-4251
C = C-4252
Blank = No surge
Orders should be entered by the military specication number, including the dash number and surge option letter (A, B or C).