Operation Manual

10
A7 MIG Gun 500-w© Kemppi Oy 2017 1712
OPERATING MANUAL
11. INSTALLING THE ROBOT GUN
Risk of injury due to unexpected start-up
For the entire duration of maintenance, servicing,
unmounting, and repair work, the following instructions
must be adhered to:
Switch o the power supply.
Cut o the compressed air supply.
Pull the power plug.
Read the safety instructions in this manual and the
separate safety instructions.
The system may only be installed by authorized personnel.
11.1 Assembling the A7 MIG Gun 500-w
neck
This section describes how to assemble the A7 MIG Gun
500-w neck.
Figure 4: A7 MIG Gun 500-w neck assembly
1
4
3
2
5
1. Gun mount
2. Four screws, M4×20
3. Cable assembly connection
4. Spring
5. Groove
Proceed as follows:
1. Unscrew the screws (2), and open the gun mount
(1).
2. Insert the cable assembly connection (3) into the
gun mount (1). Make sure that the groove (5) and
the spring (4) are positioned correctly.
3. Close the gun mount (1), and tighten the screws
(2) to a max. tightening torque M of 6 Nm.