2.5 Preparing for operation
NOTE! Cooling liquid is injurious! Avoid also contact with skin or eyes. In case of injury, seek for
medical advice.
See also 2.4.2. Main parts of cooling unit.
1. Connect the mains voltage and control connectors of the cooler unit to the
corresponding connectors on the base of the power supply. The connection can be
established through the base of the power supply when the devices are separated or
through the right side of the Cool X unit by removing the right side plate.
TEST
2. Attach the power supply on the cooler.
3. Connect the cooling water hoses with the wire feed unit, follow colour markings.
4. Fill the reservoir with cooling liquid. It is preferred to use Kemppi brand cooling liquid.
Also water can be used, if the temperature doesn't go below 0 degrees Celsius. The
capacity of the reservoir is 3 litres.
5. Switch on the power supply.
6. Press and hold down the test switch until the torch hoses are lled with liquid.
7. Refer to the graphical instruction below in order to deselect or select water-cooling
function. FastMig X operation is set to 'AUTO' from the factory. Note that welding will be
prevented if cooler function is enabled and no cooler is tted.
NOTE! When Cool X is connected to the FastMig X power source for the rst time, the cooler
function is normally active. To deselect the cooler function, follow the instructions below
depending on the power source type in use.