Operation Manual

7
© Kemppi Oy / 1515
EN
4. MAINTENANCE
NOTE! Watch out for mains voltage when handling electric cables!
In planning product maintenance machine utilization degree and circumstances should be
considered. Careful use and preventive maintenance help to avoid unnecessary production
disturbances and breaks.
4.1 Daily maintenance
The following maintenance opeations should be carried out daily:
Check water level and input ow, add liquid if needed.
Check cables and connections. Tighten, if necessary and replace defect parts.
Check that there are no leakages in the cooling water hoses.
4.2 Every sixth months
The following maintenance opeations should be carried out at least every sixth months:
Clean o dust and dirt. Change the cooling liquid and wash up the pipes and water
reservoir with pure water.
Check seals, cables and connections. Tighten, if necessary and replace defect parts.
4.3 Trouble shooting
See also 3.2. Overheat signal lamp.
Overheat signal lamp is lit.
The unit is overheated.
Check water circulation.
Check that there is enough free space behind the machine for cooling air circulation.
Error code Err 27 on the FastMig panel
Check the liquid hoses for damages.
Remove any hose blockages.
Check water circulation, add liquid if needed.
For further information and assistance, contact your nearest Kemppi service workshop.
4.4 Disposal of the machine
Do not dispose of electrical equipment with normal waste!
In observance of European Directive 2002/96/EC on waste electrical and electronic
equipment, and its implementation in accordance with national law, electrical equipment
that has reached the end of its life must be collected separately and taken to an appropriate
environmentally responsible recycling facility.
The owner of the equipment is obliged to deliver a decommissioned unit to a regional
collection centre, per the instructions of local authorities or a Kemppi representative. By
applying this European Directive you will improve the environment and human health.