Operation Manual

X8 MIG WELDER 2.3 Installation
The connection list shows the serial numbers of the available wire feeders and a power
source. Check the serial number on the device rating plate.
A connection forms between the wire feeder or power source and Control Pad. The led on the power
source lights up permanently.
Note:
Once you have created the connection, Control Pad tries to reconnect if you take it out of the
connection distance. Select Disconnect on Control Pad to disconnect the connection.
2.
You can also connect Control Pad to the wire feeder through the wire feeder control panel if the wire
feeder is far from the power source.
a) Go to Settings > Wireless devices > Connect.
The wire feeder connects automatically to Control Pad.
3.
If the buttons of the power source and wire feeder are unreachable:
a) Go to Settings > WirelessDevicesAvailable in Control Pad.
b) Move focus to a wire feeder or a power source.
c) Press the green button.
2.3.5.2 Wired connection
Control Pad makes a wired connection with X8 Power Source and X8 Wire Feeder. Connect Control Pad to a
wired connection, when wireless connection is unavailable.
Proceed as follows:
1.
To make a wired connection between Control Pad and the power source:
a) Plug the combo cable to the Control Pad connector of the power source.
The connector is marked with a Control Pad icon.
OPERATING MANUAL | EN 57
©
KEMPPI | 2018-09-28