Donotinsertanytoolor foreignobjectsinto
thevalveoutletor safetyreliefvalve.You
maydamagethevalveandcausea leak.
Leakingpropanemayresultinexplosion,fire
severepersonalinjury,or death.
If a leakisdetectedat anytime,STOPand
call thefire department.
If youcannotstopa gasleak,immediately
closetheLPtankvalveandcall a LPgas
supplieror yourfire department!
Neverattemptto attachthisgrill to theself-
containedLPgassystemof a campertrailer
or motorhomeor to anyunregulatedsource
of propane.
Donotusethisgrill untilleaktested.
Leak
1.
2.
3.
4.
Testing Valves, Hose, and Regulator
Turn all grill control knobs to OFF.
Be sure regulator is tightly connected to LP tank.
Completely open LP tank valve by slowing turning the
OPD hand wheel counterclockwise. If you hear a
rushing sound, turn gas off immediately. There is a
major leak at the connection. Correct before
proceeding by calling for replacement parts at 1-
800-4-MY-HOME®.
Brush soapy solution onto the areas indicated by
arrows in the figure below.
For Safe Use of Your Grill and to Avoid Serious
Injury:
Do not let children operate or play near your
grill. Keep pets away from your grill.
Keep grill area clear and free from materials that
burn.
Do not block holes in sides or back of grill.
Check burner flames regularly.
Use grill only in well-ventilated space. NEVER use
in an enclosed space such as a carport, garage,
porch, covered patio, or under an overhead
structure of any kind.
Do not use charcoal or ceramic briquets in a gas
grill.
Use grill at least 36 inches (914mm) from any wall
or surface. Maintain 10 ft. clearance to objects
that can catch fire, or sources of ignition such as
pilot lights on water heaters, live electrical
appliances, etc.
NEVER attempt to light burner with lid closed. A
buildup of non-ignited gas inside a closed grill is
hazardous.
Never operate grill with LP cylinder out of correct
position specified in assembly instructions.
Always close LP cylinder valve and remove
coupling nut before moving LP cylinder from
specified operation position.
5. If "growing" bubbles appear, there is a leak. Close
LP tank valve immediately and retighten connections.
If leaks cannot be stopped do not try to repair. Call
Sears for replacement parts at 1-800-4-MY-HOMI:®.
6. Always close LP tank valve after performing leak test
by turning hand wheel clockwise.
Apartment and Condominium Dwellers
Check with management to learn the requirements and
fire codes for using an LP gas grill in your complex. If
allowed, use outside on the ground floor with a three (3)
foot clearance from walls or rails. Do not use on or under
balconies.