SAFE INSTALLATION, USE AND SERVICE Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual.
GENERAL SAFETY WARNING er. 8a 0] Read and understand instruction improper installation and use may result manual and safely messages int property damage. before installing, operating or servicing this water heater. Do not operate water heater if flood damaged Failure to follow instructions and Inspect and replace the anode as needed safety messages could result in « Install in location with drainage. death or serious injury. » Fill tank with water before operation. | Be alert for thermal expansion.
PRODUCT WARRANTY NOR 4 10 YEAR LIMITED WARRANTY ON WATER HEATER For ten years from the date of purchase, if this water healer is installed and operated in a single-family home in accordance with the owner's manual instructions and all local applicable plumbing codes, Sears will 1. Supply free water heater parts for those that are defective in material of workmanship. 2.
TABLE OF CONTENTS SAFE INSTALLATION. USE AND SERVICE GENERAL SAFETY... PRODUCT WARRANTY . TABLE OF CONTENTS, INTRODUCTION PRODUCT SPECIFICATIONS MATERIALS AND BASIC TOOLS NEEDED, JR a SCS, [RS JR Materials NESTS. Basic Tools... Additional Tools Needed When Sweat Soldering . INSTALLATION INSTRUCTIONS Removing the Old Water Heater... Facts to Consider About the Location Insulation Blankets... Confined Space Installation. Water Piping System Piping Installation.
INTRODUCTION Thank You for purchasing a Sears water heater. Properly installed and maintained, it should give you years of ruble free service. It is strongly suggested that this new water heater be professionally installed, contact the local Sears Service Center or any Sears store. Hay will vanguards for prompt, quality installation by Sears authorized contractors. Abbreviations Found In This Instruction Manual: UL ~ Underwriters Laboratories Ine.
MATERIALS AND BASIC TOOLS NEEDED Materials Needed To simplify the installation Sears has available the installation parts shown below. You may or may not need all of these materials, depending on your type of installation. WATER HEATER INSTALLATION KIT WITH FLEXIBLE CONNECTORS FOR 347 THREADED OR COPPER PLUMBING.
Re aaa Eel Removing the Old Water Heater FIGURE 2. 1. Turn “OFF” electrical supply to the water heater, FIGURE 3. 2. Open a nearby hot water faucet until the water is no longer hot. When the water has cooled, turn “OFF” the water supply to the water heater at the water shut-off valve or water meter FIGURE 4, 3, Attach a hose to the water heater drain valve and put the other end in a floor drain or outdoors. Open the water drain valve.
CAUTION Mineral Buildup or Sediment May Accumulate * This causes the water heater fo become uch heavier than normal. * If spilled could cause staining. Mineral buildup or sediment may have accumulated in the old water heater.
Confined Space installation The heat pump water heaters covered in this manual require a minimum of 750 cubic feet of installation space.
Table 2 THEM WITHOUT DUCT WORK WITH 8 INCH FLEXIBLE DUCT AND OUTLET DUCT KIT LOUVERED GRILL CONFINED SPACE CONFIGURATION {door or wally MINIMUM SPACE {abi feet) 810 4850 400 128 EXAMPLE ROOM SIZE HX LXW feet) B78 x RENEGER EERIE Bad xd Installation Installation requires ability equivalent to that of a qualified VAC installer. Installation skills such as air supply, venting, and duct installation are required.
Water Piping System DANGER Water temperature over 125°F {52°C} can cause severe bums instantly resulting in severe injury or death. Children, the maidenly, and the physically or mentally disabled are at highest risk for scald injury. Feel water before bathing or showering. Temperature limiting valves are available Read instruction manual for safe temperature setting. Piping. fittings, and valves should be installed according to the installation drawing (Figure 10).
8. After piping has been properly connected to the water heater, open the nearest hot water faucet. Then open the cold water shut off valve and allow the tank fo completely fit with water. To purge the lines of any excess air and sediment, Keep the hot water faucet open for 3 minutes after a constant flow of water is obtained. Close the faucet and check all connections for leaks.
Temperature-Pressure Relief Valve Explosion Hazard Temperature-pressure relief valve must comply with ANS! 221.22 CBA 4.4 and SAME code Properly sized temperature-refief valve must be installed in opening provided Can result in overheating and excessive tank pressure. Can cause serious injury or death. This heater is provided with a properly certified combination temperature pressure relief valve by the manufacturer.
Filling the Water Heater CAUTION Property Damage Hazard + Avoid water heater damage = Fill tank with water before operating. Never use this water heater unless it is completely fut of water. To prevent damage to the tank and heating element, the tank must be filed with water. Water must flow from the hot water faucet before turning “ON” power. To fill the water heater with water: 1. Close the water heater drain valve by turning the handle to the right (clockwise).
Connect the electrical supply to the water heater NOTE: Remove the standard 1/2 inch knock-out (opening) in the junction box for conduit connections. Connect ground wire to green ground wire in the electrical Junction box of the water heater. . Reinstall the junction box cover, . Reattach the left louvered access panel to the water heater and secure it using the screws loosened earlier. Tun on electrical power to the water heater, .
INSTALLATION CHECKLIST Water Heater Location Condensate Drain Line Centrally located with the water piping system. The flooring beneath the water heater must be able to support the weight of the water heater when filled with water {See Table 1). Located indoors {such as a basement or garage) and in a vertical position. Sheltered from freezing temperatures. Provisions made to shelter the area from water damage.
SERVICE AND ADJUSTMENT Before Using 1. Make sure the water heater has been properly installed. See “Installing Your Water Heater” section. 2. Make sure the air filter is correctly seated, as it may shift during shipping or installation. See “Repair Parts Illustration” section. 3. Completely fit section). the tank with water (See “Water Piping” 4. After the water heater tank is completely filed with water, connect electrical power to the water heater.
Operating Mode Descriptions The operating modes can be changed by touching the desired mode icon on the User Interface Module (see Figure 17.) NOTE: All buttons on the User Interface are touch sensitive and require only a light touch to actuate. ® e Hybrid Mode This is the default, recommended setting. Combining high energy efficiency with reduced recovery time, this mode uses the heat pump as the primary heating source.
if after manually operating the valve, it fails to completely reset and continues to release water, Immediately close the cold water inlet to the water heater, follow the draining instructions, and replace the temperature-pressure relief valve with a new one. Failure to install and maintain a new properly listed depressurization relief valve will release the manufacturer from any claim which might result from excessive temperature or pressure.
1. Press the power button on the user interface module fo place the water heater in Standby Mode. 2. Turn off the power to the water heater. FIGURE 19, 3. Drain the water heater as directed In the “Draining and Flushing” section, A DANGER Burn hazard + Hotter discharge. + Keep hands clear of drain valve discharge. 4. Remove the access covers). then remove the foam insulation block 5. Remove the protective plastic cover(s) over the elements from their attachment point. 6.
Remove (slide) the filter from the unit If you are replacing the filter skip (o step 4. To clean the filter use a vacuum with a hose attachment to remove any dust of debris Place the new or cleaned filter info the water heater and secure the filter to the shroud with the screw loosened earlier. NOTE: Use the guideposts when inserting the filter into the water heater. Restore power to the water heater and press the power button to tum the water heater on.
TROUBLESHOOTING Start Up Conditions THERMAL EXPANSION. CAUTION Property Damage Hazard « Avoid water heater damage. » install thermal expansion tank or device if necessary. = Contact qualified installer or service agency. As water is heated, it expands {thermal expansion). In a closed system, the volume of water will grow. As the volume of water grows, there will be a corresponding increase in water pressure due to thermal expansion. Thermal expansion can cause premature tank failure (leakage).
“AIRY IN HOT WATER FAUCETS A WARNING Explosion Hazard » Flammable hydrogen gases may be present = Keep all ignition sources away from faucet when wining on hot water, HYDROGEN GAS: Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable and explosive.
DIAGNOSTIC CODES DISPLAY SHOWS INDICATES CORRECTIVE ACTION UPPER ELEMENT 1. Upper element is not Turn off power at the circuit breaker/fuse box and check for CONNECT functioning a loose connection at the element. For access directions FAULT see ‘Element Removat/Replacement” section. If error persists proceed to the next step. Replace non-functioning element. Ses “Element Removal Replacement” section. LOWER ELEMENT 1.
TROUBLESHOOTING CHART PROBLEM POSSIBLE CAUSE(S) CORRECTIVE ACTION HO HOT WATER No power to the water heater {power button not {it} Cheek for blown fuse or tripped breaker. Restore power to unit then press power button. 2. Uniting standby {power button RED} 2. Press the power button to tum the unit on (power button GREEN} 3. Uniting Vacation mode 3. Press Vacation Mode Button to exit Vacation mode and return to desired operating mode. 4. High temperature limit switch pane 4.
WIRING DIAGRAM we x = Olt. TEMP. SENSOR £2 sg a DISCHARGE TEMP. SENSOR HEAT PUMP WATER AMBIENT TEMP. SENSOR HEATER WIRING DIAGRAM fon gym TANK LOWER TEMP, SENSOR TANK UPPER TEMP. SENSOR [srl B78 Avon powered DISPLAY \ Io eat UNE Ele} A i CONNORS NEOCON cas picnics TAR Anopheles HF TEEN.
LEAKAGE CHECKPOINTS 7 = 8 Maximum Air Gap WARNING Read and understand instruction manual and safety messages before installing, operating or servicing this water heater. Failure to follow instructions and safety messages could result in death or serious injury. instruction manual must remain with water heater, Read this manual first. Then before checking the water heater make sure the electric supply has been muted “OFF”, and never turn the electric supply “on” before the tank is completely full of water.
REPAIR PARTS LIST KENMORE ELITE HYBRID ELECTRIC HEAT PUMP WATER HEATERS MODEL NUMBERS 153.321181 60 Gallon 153 321181 50 Gallon TEM MODEL NUMBER NO. PARTS DESCRIPTION 153.321161 | 163.521181 71 Upper process Cover 408230.
Your Home For troubleshooting, product manuals and expert advice: @ manageability www.managemylife.com For repair — in your home — of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner's manuals that you need fo do-it-yourself. For Sears professional installation of home appliances and items like garage door openers and water heaters.