Installation Guide
15
Install the Hood (Standard Installation)
1.  Run house power cable between service panel and 
hood location. For hood with power cable access 
located on back of hood, run the house power cable 
into the hood through the strain relief previously 
installed in step 8 on page 8. For hood with power 
cable access located on top, tighten the strain relief 
to the power cable before inserting the strain relief 
in the knockout hole.
2.  Hang hood from (2) mounting screws previously installed.
Slide hood back towards wall until mounting screw 
heads are engaged in narrow end of keyhole slots in 
top of hood. Tighten screws securely and maintain a 
hold on the hood until completing step 3.
DUCTED INSTALLATIONS ONLY
4. Connect the ductwork to the hood and use metal foil duct tape to make joints secure and air-tight. Make sure
the damper assembly (or round duct plate) enters the ductwork and that the damper opens and closes freely.
NOTE:  Two installers are recommended because of the weight of this hood.
Warranty Safety CleaningOperation Installation Service Parts
BACK OF HOOD
S
CREW PREVIOUSLY 
TIGHTENED IN STEP 2
3.  Secure the hood to the cabinet using 2 no. 8 x 5/8” 
round head wood screws and 2 washers (screws and 
washers included in parts bag). Insert 1 screw and 
washer per side, in the slots (as shown beside. Attach 
power cable to the hood using the strain relief.