Installation guide

continuedfrompage7
Forwall or roofventingmethods:
Choose betweenroof venting or wall venting.
If the wall exhaust method is chosen, be sure that there is
proper clearancewithin the wall for the exhaust vent.
Vent materialsneededfor installationare notincluded.
Wall and roofcapsmusthaveback-draftdamper.
We recommend:
v' using rigid metal vent.
v' that length of vent and number of elbows should be
kept to a minimum to provide efficient performance.
v' that size of vent should be uniform.
v' using duct tape to seal all joints inthe vent system.
v' using caulking compound to seal exterior wall or roof
opening around cap.
v' two elbows should not be installed together.
We do NOTrecommend:
v' flexible metal vent.
NOTE:If flexible metal vent must be used, calculate each
foot of flexible metal vent as two feet of rigid metal vent.
Flexiblemetal elbows count twice as much as standard
elbows.
Roofventing
Salida de alre perel cielo raso
roof cap
¢aperuzade cielo raso
3-1/4"x 10" through*the-roof
a trav_sdelcielorasoperunorificio
de3-1/4"x 10
Wall venting
Salida de alre perla pared
wallcap
caperuz_depared
3-1/4" x 10" through-the*wall
a trav6s de la paredpar un
orificio de 3-1/4" x10
Roundventtransition
Transici6nde conductode salidade aire redondo
roof cap _ _,.,-,.._
caperuzade _ / k
cielo raso
6" min. diameter roundvent _ [ [ wall sap
conductode salida de aire ] ."-_t_. ...... ._,._,..M_-,_
redondode6"dedi_metro I" I _ _---, ,_ ._-_-'.=_._
coda
3-1/4" x 10" to 6" round vent
transition
transicibndeconductodesalida
3" minimum height (required
for damper to fully open)
Altura minima de 3"
(necesaria para qua la
compaerta se abra
nompletamente)
deaireredondode3-1/4"x 16"
a6"
vienedelap_,gina7
Para m_todos desalida de aire a trav6sde la pared o el
cielo raso:
Decidaentre instalar la salida de aire a travds del cielo raso o
de una pared.
Si se decide par el mdtodo de salida deaire a travds de la
pared,aseg_resede que haya el espacio adecuadodentro de
la pared parael conducto de salida de aire.
No se incluyenlos materiales del conductode salida de aire
que se necesitanpara la instaiaci6n.
Las caperuzaspara cielorasoy pared debentener
compuertadecontratiro.
Recomendamos:
v' usar un conducto de salida de aire met_lico y rigido.
v' que la Iongitud del conducto de salida de aire y el n_mero
de codas se mantengana un minima pareIograr un
rendimiento eficiente.
v' que las dimensiones del conducto sean uniformes.
v' usar cinta pareconducto pare sellar todas las uniones en el
sistema de salida de aire.
v' usar masilla parecalafatear paresellar la pared exterior ola
abertura en el cielo raso alrededor de la caperuza.
v' no se deben instalar dos codas juntos.
No recomendamos:
v' conducto de salida de aire met_lico flexible
NOTA:si debeusarse un conducto metdlico flexible, calcule
cada pie de conducto metdlico flexible coma si fueran dos pies
de conducto metdlico rigido. Los codas de metal flexible hacen
par dos codas estdndar.
8
Recommendedventlength:
Use3-1/4° X 10" rectangular or 6" round vent.
The total length of the vent system including straight vent,
elbow, transitions, wall or roof caps must not exceedthe
equivalent of 140 feet of 3-1/4" X 10" rectangular or 6"
diameter round vent.
For best performance, use no more than three 90 degree
elbows.
To calculate the length of system you need,add the
equivalent feet for each vent piece used in the system. See
the following examples:
3-1/4"x 10" ventsystem:
1 - 3-1/4" x 10"
90° elbow = 25 ft.
1 - wall cap = 40 ft.
8 feet straight 8 ft.
Length of
3-1/4" x 10" system = 73 ft.
6"vent system:
1 - transition = 5 ft.
2 - 90° elbows 20 ft.
1 - wall cap = 40 ft.
8 feet straight 8 ft.
Length of 6" system = 73 ft.
If the existing vent is round, a rectangular-to-round adapter
must be used and a rectangular 3" extension vent between
the damper assembly and adapter must be installedto
preventdamper from sticking.
Recommendedstandardfittings
Accesoriosest_ndarrecomendados
3-1/4"x lO"to 6"=5ft.
De3-1/4"x 1_'a6"=
5pies
3-1/4'x 10"roofcap=24 ft.
Capemzadecielorasode
3-1/4"x 10'=24 pies
3-1/4"x10"
90_dbow =25 ft.
Codede90° y 3-1/4"x
1_' =25pies
90° elbow=lOft.
CododegO_=
10 pies
3-1/4"x 10"wallca
=40ft.
Coperuzadepared
de3-1/4"x 10"=
40pies
45° elbow=5ft.
Codade45° =
5 pies
3-1/4"x10'flat
eibow= 10ft.
Codapianode3-1/4"
x 10"= 10pies
3-1/4"x 10"ventsystem
Sistemade salidade aire de 3-1/4" x 10"
3-1/4" x 16"
90° elbow
Codade90° y 6 It.
3-1/4"x1_ _6pies_ n wallsap
T" ] I H_caperuzade
' I}> parud
U 2_t. (2 pies)
6"vent system
Sistemade salidade aire de 6"
90° elbows
codo de 90°
2
transition
transici6n
2 ft. (2 pies)
Longitudrecomendadadel conductode salidade aire:
Useun conducto de salida de aire rectangularde 3-1/4_x 10"
o redondo de 6".
La Iongitud total del sistema de salida de aire, incluyendo el
conducto de salida de aire recto, el coda, las transiciones, las
caperuzas de pared o cielo raso no deben excederel
equivalentea 140 pies de conducto rectangular de salida de
aire de 3-1/4" x 10" o conducto redondo de 6" de didmetro.
Paramejores resultados, no use m_s de tres codas de 90°.
Paracalcular la Iongitud del sistema que necesita,agregue la
equivalenciaen pie para cada pedazode conducto usado en el
sistema. Vealos siguientes ejemplos:
Sistemade salidade aire de 3-1/4" x 10":
1 - Coda de 90°
y 3-1/4" x 10" = 25 pies
1 - Caperuzade pared = 40 pies
8 pies recto = 8 pies
Longitud de un
sistema de 3-1/4" x 10" = 73 pies
Sistemade salidade aire de 6"
1 -transici6n = 5 pies
2 - codas de 90° 20 pies
1 - caperuzade pared = 40 pies
8 pies recto 8 pies
Longitud de un
sistema de 6" = 73 pies
Si el actual conducto de salida de aire es redondo, debe usarse
un adaptador de rectangulara redondo y un conducto de
extension rectangular de 3" entre el conjunto de la compuerta
y se debe instalar el adaptador pare evitar que la compuerta se
atasque.