721.88502 721.88503 721.88509 r-------q J Read and save these installation instructions. Lea y guarde estas instrucciones de instalaci6n MicrowaveHood Combination Combinaci6n Microondas Campana Part No. MFL57652401 Sears, Roebuck and Co., Hoffman Estates, IL. 60179 U.S.A www.sears.com.
YOUR SAFETY FIRST BEFORE YOU START • Proper installation is the installer's responsibility! - Read the entire manual before you begin. - The model number label is located on the oven front. See Figure 1. - Mounting plate is located on back side of microwave oven. See Figure 2.
YOUR SAFETY FIRST • THIS APPLIANCE MUST BE GROUNDED! - If there is an electrical short circuit, grounding reduces the risk of electrical shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. PROPERLY POLARIZED AND • Place the plug into a properly installed and grounded outlet. See Figure 3. • Do not use an extension cord. • Keep the power cord dry and do not pinch or crush it.
YOUR SAFETY FIRST • MAKE SURE YOU HAVE ENOUGH SPACE AND SUPPORT. - Mount the oven against a flat, vertical wall, so that it is supported by the wall. The wall should be constructed of minimum 2" x 4" wood studding and 3/8" thick drywall or plaster/lath. - ATTACH AT LEAST ONE of the two lag screws supporting the oven to a vertical, 2" x 4" wall stud. - DO NOT mount the microwave oven to an island or peninsula cabinet. - BE SURE the upper cabinet and rear wall structures are able to support 150 Ibs.
PARTS, TOOLS, MATERIALS THE FOLLOWING PARTS ARE SUPPLIED WITH THE OVEN: NOTE: Depending on your ventilation requirements, you may not use all of these parts.
PAR TS, TO 0 L S, MATER IA LS YOU WILL NEED THE FOLLOWING INSTALLATION: TOOLS AND MATERIALS FOR THE Carton or other heavy material for covering the counter top.
STEP 1: PREPARE THE ELECTRICAL CONNECTIONS WARNING AVOID ELECTRICAL SHOCK! A THIS APPLIANCE 1. Locate the grounded electric outlet for this oven in the cabinet above the oven, as shown in Figure 4 Detail. MUST BE GROUNDED! Upper NOTE: The outlet should be on a circuit dedicated to the microwave oven 120V, 60Hz., AC only, with a 20ampere fused electrical supply.
STEP 2: PREPARE THE VENTING S YS YTEM NOTE: The ductwork you need for outside ventilation is not included with your oven. The standard ductwork fittings and length are shown in Figure 9, page 9. WARNING THIS OVEN MUST BE PROPERLY - FIRE HAZARD VENTED! You may vent your oven in one of three ways: Roof Venting If your oven is located on an outside wall near the roof, as in Figure 6 (3-1/4" x 10" duct) and Figure 8 (6" round duct.
STEP 2: PREPARE STANDARD THE VENTING SYSTEM FITTINGS NOTE: If the existing duct is round, you must use a rectangular-to-round adapter, with a rectangular 3" extension duct installed between the damper assembly and the adapter to prevent the exhaust damper sticking. DUCT LENGTH The total length of the duct system, including straight duct, elbows, transitions, wall or roof caps must not exceed the equivalent of 140 feet. For best performance, do not use more than three 90 degree elbows.
STEP 3: PREPARE THE VENTING BL 0 WER Your microwave oven is shipped with the blower assembled for room venting (recirculating). the blower if you want wall vented or roof vented installation. You need to adjust WARNING ELECTRICAL SHOCK HAZARD! UNPLUG UNIT BEFORE WORKING ON IT. o DO NOT PULL OR STRETCH THE BLOWER WIRING! Pulling and stretching the blower wiring could result in electrical shock. REMOVE THE MOUNTING A thick, protective covering PLATE: 1.
STEP 3: PREPARE WALL VENTED THE VENTING BLOWER INSTALLATION: 1. Remove blower unit mounting screw(s) and blower plate screw(s). Remove the blower plate from cabinet. See Figure 12. -- back plate blower unit blower plate mounting screw(s) (option) 2. Carefully lift the blower unit out of the microwave oven. Disconnect the blower wire from connector. See Figure 13. Knockouts "B" 3. Use side cutters or tin snips to cut and remove knockouts "B" from Back plate. Discard knockouts.
STEP 3: PREPARE ROOF VENTED THE VENTING BL 0 WER INSTALLATION: 1, Remove blower unit mounting screw(s) and blower plate screw(s). Remove the blower plate from cabinet. See Figure 18. 2, Carefully lift the blower unit out of the microwave oveR. plate mounting screw(s) (option) "_- 3. Rotate blower unit 90 ° so the exhaust ports face the top of the cabinet. See Figure 19. "o blower plate blower unit mounting screw(s) (option) 4. Place blower unit back into microwave oven. Figure 18 5.
STEP 4: PREPARE THE WALL AND UPPER CABINET FOR INSTALLATION MEASURE AND TACK / TAPE UP THE TEMPLATE 1. Using a plumb line and (metal) measuring tape, find and mark the vertical center line ,_ on the back wall, as in Figure 22. O 2. Find and mark one or two points where the studs are on the wall (Studs are normally 16 inches apart.) and then measure and mark the stud locations. If you cannot find any wall stud, consult a local building contractor.
STEP 4: PREPARE THE WALL AND UPPER CABINET FOR INSTALLATION DRILL THE HOLES IN THE WALL AND UPPER CABINET. WARNING BE VERY CAREFUL WHEN DRILLING HOLES INTO THE WALL. Electrical wires could be concealed behind the wall covering and if the drill hits them you could get an electric shock. 1. Find the points on the mounting plate labeled "A", "B", "C" and "D". Drill a 3/16" diameter hole at any of these points that are in front of a wall stud.
STEP 5: INSTALL THE MOUNTING PL ATE TO THE WA L L THE OVEN MUST BE CONNECTED TO AT LEAST ONE WALL STUD. 3/16 Hole on Studs 5/8 Hole on Drywall Only I Minimum 66" I FromtheFloor I 1. Draw a vertical line on the wall at the center of the 30" wide space. r---- °rwa W nted C UL/IL Use the mounting plate as the template for the rear wall. Place the mounting plate on the wall, making sure that the tabs are against the bottom of the cabinet.
STEP 5: INSTALL THE MOUNTING PL ATE TO THE WA L L TO PREPARE THE REAR WALL CUTOUT OPENING AND EXHAUST ADAPTOR/MOUNTING PLATE FOR WALL VENTING AND ROOF VENTING: • Make the box cutout for the rear wall duct. - 1 piece mounting plate: Using a pencil, put dots through slots F and G, and through holes H and I. Remove the mounting plate and draw lines extending through the points. This will give the location and size of the box cutout for the rear wall duct.
STEP 6: ATTACH THE 0 VEN TO THE WALL WARNING A You will need two people to lift this microwave, Failure to use more II power cord than one person could result in personal injury, )ower cord hole 1. Carefully lift microwave oven and hang it on support tabs (See Figure 26) at the bottom of the mounting plate. Reaching through upper cabinet, thread power supply cord through the power supply cord hole in the bottom of the upper cabinet. See Figure 30. 2.
STEP 6: ATTACH THE OVEN TO THE WALL 5. Roof vented installation: See Figure 32. Install ductwork through the vent opening in the upper cabinet. Complete the venting system through the roof according to the method needed. See "PREPARE THE VENTING SYSTEM," STEP 2 on the page 8. Use caulking to seal exterior roof opening around the exhaust cap. See Figure 6 on page 8. Figure 32 6. Use power supply cord clamp to bundle the power supply cord.
MEMO 19
Printed in Korea