Installation guide

2. If connecting to a 4-wire supply cable (also
mobile homes): The white neutral wire from the
power supply cable must not be connected to the
junction box.
Connect the green (or bare copper) wire from the
appliance cable and the supply cable (green or bare)
wire to the ground screw inside the junction box (see
Figure 5). Cap the white neutral wire from the power
supply cable. Connect the remaining wires inside the
junction box from the power supply cable to the
matching colors of the appliance cable wires.
Ground Wire
Red
Wires
Cable from Power Supply
White Wire
Black
Wires
Ground
(Bare or
Green Wire)
Cable from appliance
Box
U.L.-Listed
Conduit
Connector
Figure 5
4-WIRE GROUNDED JUNCTION BOX
r,!,_vg_,_:t_tl_[_DO NOT ground to a gas supply pipe.
DO NOT connect to electrical power supply until
appliance is permanently grounded. Connect the
ground wire before turning on the power.
Cooktop Installation
1. Visually inspect the cooktop for damage. Also make
sure all cooktop screws are tight (see Figure 6).
Screws
Figure 6
2. Set the cooktop into the countertop cutout.
NOTE: Do not use caulking compound; cooktop should
be removable for service when needed.
r!,vAvl_.Itl_ll_[=]lDo not remove the nylon spacers on
the edges of the cooktop. These spacers center the
cooktop in the space provided. The cooktop must
be centered to prevent excess heat buildup that
may result in heat damage or fire (see Figure 7).
6 Nylon spacers+
Position brackets
/
centerlineĀ°nunit cutout ;: +::-+- A_sz ...........
2 Retainer ........
brackets ..........