Installation Guide
ELECTRICAL CONNECTIONS
10
4-WIRE CONNECTION: CONDUIT
 • The white middle (neutral) wire of the power 
cord or 4-wire conduit must be connected to the 
middle post of the main terminal block. The other 
two wires of the power cord or conduit must be 
connected to the outside posts of the main terminal 
connection block. The fourth, ground wire (green) 
must be connected to the frame of the range with 
the ground screw. 
− Failure to do so can result in electric shock, severe 
personal injury or death.
 WARNING
1.  Follow the instructions under “Install the conduit as 
follows” on page 9 to correctly install the strain relief.
DO NOT install the conduit without a strain relief.
2.  Loosen the 2 lower left and right screws from the 
terminal block. (Refer to Figure 12.)
Remove the lower 2 center screws. Do not discard any 
screws.
3. Remove the ground screw and bend the end of the 
ground strap up so the slot is over the hole of the center 
screw removed in step 2.
4.  Attach the ground bare wire end to range frame and 
secure it in place with the ground screw (Refer to figure 
12.)
5.  Insert the bare wire (white/neutral) end through the 
center terminal block opening. The center screw now 
attaches the bent up ground strap to the block.
6.  Insert the two side bare wire ends into the left and the 
right terminal block openings.
Tighten the 3 screws securely into the terminal block. 
(approximately 35 - 50 IN-LB)
7. Go to page 11.
4-wire connection
Bend strap 
up and 
attach
Terminal 
block
Wire 
ends
Conduit
connection plate
Black White Red
Ground 
strap
Ground 
Wire
Ground 
Screw
FIGURE 12