Installation Guide
PREPARING FOR INSTALLATION
6
Save for the use of the local electrical inspector.
 NOTE
For installation in CANADA, a Free-standing range is 
not to be installed closer than 
15
/32" (12mm) from any 
adjacent surface.
DIMENSIONS AND CLEARANCES
 • The wall covering, countertop and cabinets 
around the range must be able to withstand the 
heat (up to 194°F) generated by the range.
− Discoloration, delamination or melting may 
occur.
− This range has been designed to comply 
with the maximum allowable wood cabinet 
temperatures of 194°F.
 CAUTION
 • Avoid installing cabinets directly over the range.
 • If cabinets are installed over the range, install a 
range hood that projects horizontally a minimum 
of 5 inches beyond the bottom of the cabinets.
− Doing so will reduce the risk of burns or fire 
caused by reaching above the heated surface 
elements.
 CAUTION
2.5”
(6.3cm)
6”
(15.2cm)
9”
(23cm)
9”
(23cm)
11”(28cm)
15”(38cm)
4”
(10cm)
4”
(10cm)
5”
(13cm)
Wall
Center
Cabinet
Cabinet
opening
Normal
countertop
depth
Countertop
height
2.5”(6.3cm)2.5”(6.3cm)
6”
(15.2cm)
6”
(15.2cm)
MINIMUM DIMENSIONS (Figure 2)
  *  30" (76.2 cm) minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or 
metal cabinet; or 24" (60.9 cm) minimum when bottom of wood or metal cabinet is protected by not less than 
1
/4" (6.4 
cm) flame retardant millboard covered with not less than no. 28 MSG sheet steel, 0.015" (0.381 mm) stainless steel, 0.024"  
(0.610 mm) aluminum or 0.020" (0.508 mm) copper.
**  15" (38.1 cm) minimum between countertop and adjacent cabinet bottom.
FIGURE 1
FIGURE 2
A = 30" (76.2 cm) For U.S.A 
= 30" to 31" (76.2 to 78.7 cm) For CANADA
 • Use two or more people to move and install range. 
(Excessive Weight Hazard)
– Failure to do so can result in back injury or other 
injury.
 • Do not use the oven handles to push, pull, or move 
the range.
− Doing so can result in serious damage to the door 
of the range.
 WARNING