Product Warranty

Output lead
connections not
connected.
Problem
Prevention/Solution
Troubleshooting - Electronic Ignition
SECTION I
No sparks appear at
any electrodes when
control knob turned
to HI: no noise can
be heard from spark
module.
Possible Cause
Battery not installed
properly.
Dead battery.
Button assembly not
installed properly.
Faulty spark module.
Check battery orientation.
Has battery been used
previously?
Check to insure threads are
properly engaged. Button
should travel up and down
without binding.
If no sparks are generated
with new battery and good
wire connections, module is
faulty.
Install battery (make sure that “+” and “-
connectors are oriented correctly, with “+” end
up and “-” end down.)
Replace battery with new AA-size alkaline
battery.
Unscrew button cap assembly and reinstall,
making sure threads are aligned and engaged
fully.
Replace spark module assembly.
SECTION II
No sparks appear at
any electrodes when
control knob turned
to HI; noise can be
heard from spark
module.
Are output connections
on and tight?
Remove and reconnect all output
connections at module and electrodes.
SECTION III
Sparks are present
but not at all
electrodes and/or
not at full strength
Output lead
connections not
connected.
Electrical arc
between output wires
and grill frame.
Weak battery.
Electrodes are wet.
Electrode(s) cracked
or broken; sparks
appear where
cracked.
Are output connections on
and tight?
If possible, observe grill in
dark location. Operate
ignition system and look for
arcing between output
wires and grill frame.
All sparks present but
weak or at slow rate.
Has moisture accumulated
on electrode and/or in
burner ports?
Inspect electrodes for
cracks.
Remove and reconnect all output connections
at module and electrodes.
If sparks are observed other than from
burner(s), wire insulation may be damaged.
Replace wires.
Replace battery with a new AA-size alkaline
battery.
Use paper towel to remove moisture.
Replace cracked or broken electrodes.
Check Item
48588-30800367·33