Installation Instructions (cont'd)
Temperature-Pressure
Relief Valve
_,WARNING
At the time of manufacture this water heater was provid-
ed with a combination temperature-pressuresrelief valve
certified bya nationally recognized testinglaboratory that
maintains periodic inspection of production of listed
equipment or materials, as meeting the requirements for
ReliefValvesand Automatic Gas ShutoffDevicesfor Hot
Water Supply Systems, and the latest edition of ANSI
Z21.22 and the code requirements of ASHE. If replaced,
the valve must meet the requirements of local codes,but
not less than a combination temperature and pressure
relief valve certified as meeting the requirements for
ReliefValvesand Automatic Gas ShutoffDevicesfor Hot
Water SupplySystems,ANSI Z21.22 bya nationallyrecog-
nizedtesting laboratory that maintainsperiodicinspection
ofproductionof listed equipment or materials.
The valve must be marked with a maximum set pressure
not to exceedthe marked hydrostaticworking pressureof
the water heater (150 Ibs./sq.in.) and a dischargecapacity
not lessthan the water heater input rate asshownon the
model rating plate. (Electric heaters - watts divided by
1000x 3415 equal BTU/Hr. rate.)
Yourlocaljurisdictionalauthority,while mandatingthe use
of a temperature-pressure relief valve complying with
ANSI Z21.22 and ASME, may require a valve model differ-
ent from the onefurnishedwith the water heater.
Compliance with such local requirements must be satis-
fied bythe installeror end userof the water heater with a
locally prescribed temperature-pressure relief valve
installedin the designatedopeningin the water heater in
daceofthe factory furnishedvalve.
For safe operation of the water heater, the relief valve
must not be removed from it's designated opening or
plugged.
The temperature-pressure relief valve must be installed
directly into the fitting of the water heater designatedfor
the relief valve. Position the valve downward and provide
tubing sothat any dischargewill exit onlywithin 6 inches
above, or at any distance below the structural floor. Be
certain that no contact is made with any live electrical
)art. The discharge opening must not be blocked or
reduced in sizeunder any circumstances.Excessivelength,
over 30 feet, or use of more than four elbowscan cause
restriction and reduce the dischargecapacityofthe valve.
No valveor other obstructionisto be placedbetween the
relief valve andthe tank. Do not connecttubingdirectly to
dischargedrain unlessa 6" air gap is provided.To prevent
bodilyinjury,hazard to life, or property damage, the relief
valve must be allowed to discharge water in quantities
shouldcircumstancesdemand. If the dischargepipe is not
connectedto a drain or other suitable means, the water
flow may causepropertydamage.
The DischargePipe:
Must not be smaller in sizethan the outlet pipe sizeof
the valve, or have any reducing couplings or other
restriction.
Must not be pluggedor blocked.
Mustbe of material listedfor hot water distribution.
Must be installed so as to allow complete drainage of
boththe temperature-pressurerelief valve,and the dis-
chargepipe.
Mustterminate at anadequatedrain.
Mustnothaveanyvalvebetweenthe relief valveandtank.
,WARNING
The temperature-pressure relief valve must be manually
operated at leastonce a year.Caution shouldbe taken to
ensurethat (I) no one is in front of or around the outlet
of the temperature-pressure relief valve discharge line,
and (2) the water manually dischargedwill not causeany
bodily injury or property damagebecausethe water may
beextremely hot.
If after manually operating the valve, it fails to complete-
ly reset and continues to release water, immediately,
close the cold water inlet to the water heater, follow the
draining instructions,and replace the temperature-pres-
surerelief valvewith a new one.
H_OT ( COLD
SHUT-OFF
VALVE
CONDUIT J
FLOOR DRAIN
TEMPERATURE-
J PRESSURE
RELIEF VALVE
DISCHARGE PIPE
Do not cap or plug)
6" AIR GAP
r
WARNING "RELIEF VALVE OPENING"
Thiswaterheateris p_ovidedwilha co,_on Tempe_ Press_eRe_efValvelistedasco_plyingw_h
thestandardfo_RediQfValwsandAulomalicGasShutoffDewcesforH01WaterSupp_Systems,ANSZ2122
andthecoderequirementsofASME
Yc_'lc_ judsd_tl,0nalau_hontywhle rn_ndatingtheuseofa Tempetatule-Pr_suleRelLefValve_¥rg
withANS72122andASME,may_Ie a vah.emodeldlffelentPoretheonefurnished_ thewaterheater
Comp_ar_ewithsuchlocalrequirementsr_st be_ltisfbedbytheinslallerc_endt_el of thewaterheater_h
a legally prescribedTempelalure-PteSsLJreRe[_elValveinstalledin the designatedepe_ir,g inthe wafer
heate_
TANK : ' _ ; t, JACKET
, r_.,
TANK * 1" BRASS
FITTING COUPLING
VALVE PROBE TEMPERATURE-
MUST EX_rEND PRESSURE
iNTO TANK RELIEFVALVE
BRASS SHANK
I1 a short shank (less lhan 2") temperature-pressure reqief valve is Io be installe_J
(as shown}, a nipple and coup_in 9 must be used
If a long shank (2" of loiter) is IO be in sla_led d<Jriot us_ the nipple end coupling
"Ins{all Tempetalure.Pre_ure prolective equipmenl _uir_ by local codes but nol less If,an a combine
lion Temperature-P,sssui8 Relic I Valve cetli{ied as meeting the requirernenls lot Reliel Valves and
Aulomauc Gas Shuloff De_,-_es for Hot.Waler Supply Syslems ANS Z21 22 by a helically recognized test.
rig labO_alory that r_ant ains peno_c ft_spection of production o{ lisle_ equipment el rnatehals The valve
mUSl he onenled provKled _th lubin9, or olhen_se i_slaJlod SOthat discUarge can exit only _thin 6 inches
above¸ o, at any d_stance below Ibe 5tnJcforel flOOr,and cannot contact any live electlica_ part
For safe operalio_ of the water heatel, the Rehef Valve must not be iemoved or plugged¸
See maflua_ headirlg. "Temperah_re Pressure Relief Valve" {of il_slallatitl_ and mainlenance of Relief
Valve, discharg_ p_pe and elher salety pr_autions