Installation Instructions (cont'd)
Temperature-Pressure Relief Valve
AWARNING
At the time of manufacturethiswater heater was provided
witha combinationtemperature-pressuresrelief valvecertified
bya nationally recognized testinglaboratorythat maintains
_eriodicinspectionof productionof listedequipmentor mate-
rials, as meeting the requirements for Relief Valves and
AutomaticGasShutoffDevicesforHot Water SupplySystems,
and the latest editionof ANSI Z21.22 and the code require-
mentsofASME. If replaced,the valvemustmeet the require-
mentsoflocalcodes,but not lessthan a combinationtempera"
ture and pressurerelief valvecertifiedas meetingthe require-
mentsfor ReliefValvesandAutomaticGasShutoffDevicesfor
Hot Water SupplySystems,ANSI Z21.22by a nationallyrecog-
nized testinglaboratorythat maintainsperiodicinspectionof
productionoflistedequipmentor materials.
The valvemustbe markedwith a maximum setpressurenot
to exceedthe marked hydrostaticworking pressureof the
water heater(150 IbsJsq.in.)anda dischargecapacitynot less
than the water heaterinputrate ..as.shownonthe model rating
plate.(Electric heaters- watts dlvtdedby 1000x 3415 equal
BTU/Hr.rate.)
Yourlocaljurisdictionalauthority,whilemandatingthe useof a
temperature-pressurerelief valvecomplyingwithANSI Z21.22
and ASME, mayrequirea valvemodel differentfrom the one
furnishedwiththe waterheater.
Compliancewith suchlocalrequirements mustbe satisfiedby
the installeror enduserof the water heaterwith a locallypre-
scribedtemperature-pressure relief valveinstalledin the desig-
natedopeningin the water heaterin placeof the factory fur-
nishedvalve.
Forsafeoperationof the water heater,the relief valvemustnot
be removedfromit'sdesignatedopeningor plugged.
The temperature-pressurerelief valvemustbe installeddirectly
intothefittingofthewaterheaterdesignatedfortherelief valve.
Positionthe valvedownwardand providetubing sothat anydis-
chargewill exit onlywithin 6 inchesabove,or at anydistance
below the structuralfloor.Be certainthat no contactis made
withany liveelectricalpart.The dischargeopeningmust notbe
blockedor reducedin sizeunderanycircumstance_Excessive
length,over30 feet,or useof morethan fourelbowscancau_
restrictionandreducethe dischargecapacityofthe valve.
No valveor otherobstructionisto be placedbetweenthe relief
valveand the tank.Do not connecttubingdirectlyte'discharge
drainunlessa6" airgapisprovided.Topreventbodilyinjury,haz-
ardto life,or propertydamage,the reliefvalvemust be allowed
to dischargewater inquantitiesshouldcircumstancesdemand.If
the dischargepipeisnot connectedto a drainor othersuitable
means,the waterflowmaycausepropertydamage.
The DischargePipe:
Must not be smallerin sizethan the outletpipe sizeof the
valve,or haveany reducingcouplingsor otherrestriction_
Mustnot bepluggedor blocked.
Mustbe of materiallistedforhotwaterdistribution.
Must be installedsoas to allow completedrainageof both
the temperature-pressurerelief valve, and the discharge
pipe.
Mustterminateat an adequatedrain.
Mustnot haveanyvalvebetweentherelief valveandtank.
AWARNING
The temperature-pressure relief valve must be manually
operated at least once a yea_ Caution shouldbe taken to
ensurethat (I) no one is in front of or aroundthe outlet of
the temperature-pressure relief valvedischargeline,and (2)
the water manually discharged will not causeany bodily
injury or property damage because the water may be
extremely hot.
If after manually operatingthe valve, it failsto completely
reset and continuesto release water, immediatelyclosethe
cold water inlet to the water heater, follow the draining
instructions,and replace the temperature-pressure relief
valvewith a new one.
HOT
PRESSURE
RELIEF VALVE
SHUTOFF
VALVE
_IPE
(Do not cap or
plug. Must termi-
nate beneath
Mobile Home.)
RELIEFVALVEOPENING
At the timeof manufacture,this waterheaterwasprovidedwithacombinationtem-
perature-pressurerelief valve listed ascomplyingwi_ the s_ndard for relief valvesand
automatlc gas thut-off devicesfor hot water supplysystems,ANSI Z21.22. For safe
operationofthe waterheater,the reliefvalvemustnot beremovedfromiUdesignated
point of installationor plugged.
Yourfocaljurisdictionalauthority,whilemandatingthe useof a temperature-pressure
relief valvecomplyingwith ANSI 7.21.22 andASME, may require a valvemodel different
from the one furnishedwith the water heater
Compliancew_ suchlocalrequirementsmustbesatisfiedbythe installeror enduser
of the water heater with a locallyprescribedtemperature-pressure relief valve installed
in the designatedopeningin the water heater
Seemanualheading-"Temperature-PressureReliefValves"for installationandmainte-
nanceof relief valve,dischargeline,andother safetyprecautions.
13