Manual
1. Determine whether hood will discharge vertically (3¼" x
10" or 7" Round), horizontally (3¼" x 10" only) or non-
ducted.
For vertica! or horizonta! discharge, run ductwork between
the hood location and a roof cap or wall cap.
For best results, use a minimum number of transitions and
elbows.
ROOF CAP
3¼" X 10" or
7" ROUND DUCT
(For vertical discharge)
HOUSE WIRING
or Back of hood)
I
24" - 30" ABOVE
COOKINGSURFACE
3¼" X 10" DUCT
(For horizontal discharge)
2. Use these diagrams for proper placement of ductwork and
electricaJ cutout in cabinet or wall.
For a non-ducted installation, DO NOT cut a duct access
hole.
3¼" X 10" 1
HOOD MOUNTING SCREWS (4) VERTICAL DUCTING
3. Run house wiring between service panel and hood
location.
t ELECTRICAL
ACCESS HOLE
WOOD SHIMS CENTER
(recessed-bottom UNE (in cabinet bottom)
cabinets only)
7" ROUND i
VERTICAL DUCTING
HOOD MOUNTING SCREWS (4)
1 015/16" (24" hood) 1 015/16" (24" hood)
1315/16" (30" hood) (30" hood)
DUCT
WOOD SHIMS t
(recessed-bottom CENTER
cabinets onmy) LmNE
ELECTRICAL
ACCESS HOLE
(in cabinet bottom)