Manual

8.3ΒΌ"x 10"DuctedDischargeOnly:RemoveTa_.from
damperflapandattachDamper/Duct Connector over
knockout opening with screws removed in Step 4 under
"PREPARE THE HOOD". Make sure damper Pivot is nearest
to Top/Back Edqe of hood,
9. 7" Round Ducted Discharge Only: Re-install 7" Round Duct
Plate removed in Step #1 under "PREPARE THE HOOD".
Install a 7" round damper (purchase separately). Damper
flap must open freely in direction of airflow (away from range
hood).
_-_1 To accomodate off-center ductwork, the Damper/
Duct Connector can be installed up to 1-inch on
either side of hood center or the 7" Round Duct
Plate can be installed up to W' on either side of
hood center. In extreme off-center installations,
one end of the duct connector may need to be
trimmed to clear the electrical cable clamp.
10.
Non-Ducted Installations Only: Require a Perfqrmance
Ring to be attached to the blower wheel.
To install ring:
1. Remove the Blower Wheel by rocking it side to side
and applying a slight force to pull wheel from motor.
Remove Retaining Ring if necessary,
2, Slide the ring onto the Small Diameter End of the
wheel and down to the Stop Edge of the wheel.
3. Reassemble wheel to motor. Make sure _Tabon
wheel fits into one of the Motor Slots.
4,
5.
Push wheel down until it is locked in place.
Check that wheel is properly positioned as shown,
Press Sections into place if necessary, Make sure
wheel turns freely.
UPTO 1"
SIDE-TO-SIDE
ADJUSTMENT
TAPE
TOP/BACK
EDGE
DAMPER/
DUCT
CONNECTOR
(Vertical
discharge
position shown)
SLOTS
I
STOP
EDGE z
2
O
t_
9