Kenmore 1700 11 GALLON CENTRAL HUMIDIFIER Installation Maintenance Repair Parts Troubleshooting Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
contents WARRANTY ........................................... 2 BEFORE YOU START Rules for Safe Installation and Operation ................................... 2 Tools and Materials Needed .................. 2 UNDERSTANDING HUMIDITY .............. SELECTING A LOCATION ..................... DISASSEMBLY/CONVERSION ............. INSTALLATION ...................................... WATER SUPPLY ................................... 3 4 4 5 6 HUMIDISTAT .......................................... OPERATION .......
THANK YOU? Thank you for selecting a Sears Humidifier. It will provide years of service if you give it a little care, UNDERSTANDING HUMIDITY Humidity can be puzzling, it cannot be seen, heard, touched, smelled or tasted. Many people do not understand what a humidifier will or will not do. Probably the best way to judge whether the humidity is too high, too low or about right is to watch your windows. If they are heavily fogged you most likely have too much. If there is no moisture on TYPICAL 1.
selecting a location Consider these points as you choose the location for your humidifier. Supply Air 9 inch minimum 36 inch maximum hose provided* Locate humidifier on supply air plenum (Fig. 1) or return air plenum. If the humidifier is installed on the return air plenum, the flexible hose, round opening, is connected to the supply air plenum. using flex * Purchase additional hose for greater spans.
installation MotorBracket (on sheet metal plenums) FIBER PLENUM DUCTS NOTE: The mounting screws supplied are for standard installation on sheet metal plenum ducts. If you have fiber plenum ducts, install the humidifier and components with thru-bolts, nuts, and washers (not supplied). If necessary, reinforce the humidifier mounting area on fiber ducts with sheet metal and provide additional bracing as required to support the weight of the humidifier and water.
Screws (2) If Necessary -Drill (3) Holes 1/8" Dia. O Top Humidifier "_t ar/ _.5" Minimum Clearance - Cut Opening Plenum---> o • Level Line & Bottom of Humidifier i 6 It is best to install an overflow line. Local codes may require overflow protection. The overflow is in the bottom of the reservoir (Fig. 15). Use 1/2" inside diameter plastic or rubber tubing to connect and route to nearby floor drain. (Tubing not furnished. Available at your local hardware store.
Turnhandleclockwise untilithaspierced thewater lineandvalveis completely closed(Fig.16). ,_ Partially uncoilthetubing.Slidethebrasscompressionnutoverthetubing. Thethreadsinthenutmustfacethe tubingend.Placethebrasscompression sleeveasshownin NOTE: Wire bearing support must be bent slightly inward to insure snug engagement of media wheel with media motor. Adjust as required by bending wire slightly inward before installing media wheel.
humidistat Run low voltage wire through the wall. Exit hole must be within the lower backplate wire as required.) The humidistat is designed to mount on the cold air plenum of your furnace or on an interior wall of the home. The cold air plenum, however is the preferred location for sensing the average humidity throughout your home. Select your location and follow the appropriate instructions. NOTE:COLD THE AIR HUMIDISTAT SUPPLIED IS(FIG. ASSEMBLED FOR PLENUM AS INSTALLATION 21).
SPLASH INSIDE HUMIDIFIER: Hole In Wall Mountin( Screws This humidifier depends on the difference of air pressure between the supply air plenum and the return air plenum to propel air through the humidifier. Some furnaces have higher pressures than others. This could result in air travelling at high speed through the humidifier. This can cause droplets of water to be picked up and splashed against the inside of the humidifier case. Eventually a coating of lime will build up.
12. Close top metal hinged cover and replace front plastic cover. SUMMER 13. Plug in transformer. Unplug transformer, close saddle valve, close bypass damper. (CLEAN PER ABOVE AND LEAVE RESERVOIR EMPTY.) As a reminder, you may want to put a tag or sticker on the unit indicating it has been shut down for the summer and will require start up in the fall. 14. Turn humidistat to "test" momentarily and check for media wheel rotation.
repair parts KENMORE "1700" CENTRAL MODEL NO. 303.14601 HUMIDIFIER I I I I I / KEY NO. PART NO.
Kenmore 303.14601 FURNACE HUMIDIFIER MAINTENANCE NOTE: APPLY THIS LABEL WHERE IT WILL BE EASILY SEEN AND SERVE AS A REMINDER TO PERFORM THIS ROUTINE SERVICE. Regular cleaning is necessary to keep the parts free of lime deposits. Service every month during the heating seasonor more often depending on the water conditions. 1. Unplug transformer. 2. Close saddle valve. 3. Remove front plastic panel and lift up top hinged cover. 4. Pull out pivot pin and remove float and float arm. 5.
Kenmore 1700 11 GALLON CENTRAL HUMIDIFIER For the repair or replacement parts you need Call 7:00 a.m. - 7:00 p.m., 7 days a week 1-800-366-PART (1-800-366-7278) For in-home major brand repair service Call 24 hours a day, 7 days a week 1-800-4-REPAIR (1-800-473-7247) For the location of a Sears Repair Service Center in your area Call 24 hours a day, 7 days a week 1-800-488-1222 For information on purchasing a Sears Maintenance Agreement or to inquire about an existing Agreement Call 9:00 a.m.