Kenmore 2700 17 GALLON CENTRAL HUMIDIFIER Installation Maintenance Repair Parts Troubleshooting Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
contents WARRANTY ........................................... BEFORE YOU START Rules for Safe Installation 2 and Operation ................................... 2 Tools and Materials Needed .............. 2 UNDERSTANDING HUMIDITY .............. 3 SELECTING A LOCATION .................... 4 INSTALLATION...................................... 4 DISASSEMBLY...................................... 4 WATER SUPPLY ................................... 6 HUMIDISTAT..........................................
THANK YOU! Thank you for selectinga Sears Humidifier.It willprovideyears of service if you give it a littlecare. UNDERSTANDING HUMIDITY Humiditycan be puzzling. It cannot be seen, heard, touched, smelledor tasted. Many people do not understandwhata humidifier will or will not do. them at all, especiallyin the corners,you have too little. (NOTE: Moisturewill not normallyformon thermopaneor whenstorm win. dows are used.
selecting a location Consider these points as you choose the location for your humidifier. Locate humidifieron supply air plenum(Fig. 1) or return air plenum. Ifthe humidifierisinstalledon the rstumair plenum,the flexible hose, roundopening, is connected to the supplyair plenum. 16 inch minimum 40 inch maximum using flex hose provided* • Purchaseadditional hosefo_greater spans.
[] 1 6 Mark a level line on the supplyair plenum (Fig. 6). [] Drillthe four holesmarked on the plenum with a 1/8" drillbit. Holes mustbe locatedat end of slot (Fig. 7). [] 7 Attach the humidifiercase assembly on the plenum using4 #8 screwsprovided. Level Line 1 Drill4 1/8" Holes 4" Min. Sup,ply Air J_ Furnace Cut Along-This Line i Plenum [] 2 _tcou[ This Area • Hold case assembly againstthe plenum with bottom edge ofrear openingon level line.
installation [] 11 Attachcollarand flexiblehoseto cold air plenumusing(5) #8 screwsprovided.Ifaddifionaiflexiblehoseis requiredan eightfoot length is availablethroughthe partsdepartment,order 28115205. Beforeflghtening screwsinsertdamperbetweencollar and plenum (Fig. 10). It shouldbe open for humidifieroperation. WATER SUPPLY I [] 1 Waterforthe humidifiermustbetakenfroma nearby coldwater line.Turn offthewater supply.Drain byopeninga faucet at a lowerlevel ofthe line.
[] 7 Unwind the rest of the tubing. Take care not to Idnk it. Run the tubing along flat surfaces to the humidifier. Support the tubing as needed to avoid contact with furnace. NOTE: The humidistat as supplied is assembled for return air plenum installation (Fig. 16.). RETURN AIR PLENUM MOUNT [] 1 [] 8 Close previouslyopened faucet.Turn on main water supply.Place a pail under the end of the tubing.Open the saddlevalve. Flush the line. Make sure there are no leaks along the lineor at the valve.
WIRING TOCONSTANT 120VACUNE EXTERNAL TOFURNACE Junction _ _U [] 6 Usinglowvoltagewire supplied,connectspadeter- J Ill I IIII IIII Inllal SiI# _ddl In Rltum Air Plenum (_ _-._lly _ o=_s) Pu_ thisacce_loty separately ifneeded. Av=_ _o_ s_-s P,_,_ Ser_= I minalsto solenoidvalve on top of humidifier. J NOTE: Wiring mustconformto localcodes. [] 7 [] 12 [] 8 Feed wires thru opening in humidistatback plate and attachto screwterminals.Mounthumidistaton retumair plenum using (4) #8 screwsprovided.
SPLASH INSIDE HUMIDIFIER: coating of lime will build up. It could, in extreme cases, cause leaking of water from the humidifier. This humidifier depends on the difference of air pressu re between the supply air plenum and the return air plenum to propel air through the humidifier. Some furnaces have higher pressures than others, This could result in air traveling at high speed through the humidifier. This can cause droplets of water to be picked up and splashed against the inside of the humidifier case.
I [] 8 Set humidistataccordingto outdoortemperatureas instructedon operation instructionlabel. Do not leave in 'test" position.Your humidifiershould now be ready for many more monthsol trouble-freeoperation. flowcontrolorificewhichmustbe in placefor properoperation of your humidifier.(if not installed,too much waterwill CAUTION: This special fitting contains a brass filter and flow and may cause leaking.
repair parts CENTRAL SYSTEM HUMIDIFIER MODEL NO. 303.147012 KEY NO. 1 2 3 4 5 6 7 8 PART NO. 21597201 33521001 21595101 21594201 21594101 21594001 21601101 35561801 9 10 11 12 13 14 STD575025 STD575026 03001804 03028705 05291201 21597701 15 16 17 18 21598701 25514001 35587901 21582703 DESCRIPTION KEY NO. PART NO. Case Assembly Media Pad (42-14711 ) Front Panel Speed Clip Rubber Washer Plastic Eyelet Boot Saddle Valve 19 20 21 22 23 24 25 26 (Includes Key Nos.
Kenmore 303.14701 FURNACE HUMIDIFIER MAINTENANCE (APPLY THIS LABEL WHERE EASILY SEEN) Cleaning frequency is dependent upon mineral content of water supply. Check every 60 Days until schedule can bd determ_ned. CAUTION: Before performing service, inspection, or maintenance: off water at humidifier saddle valve, wear safety glasses. Turn off electricity to furnace and humidifier, turn SERVICING THE MEDIA PAD 1. Lift off front panel. 2.
Kenmore 2700 17 GALLON CENTRAL HUMIDIFIER For the repair or replacement parts you need Call 7:00 a.m. - 7:00 p.m.