Quick Start Manual

Before Starting
Tools you will need
For leveling legs and antl-tip brackets: _-._ _"_,_i-\,
Adjustable wrench or channel lock pliers ......._s_ ....
5/16" Nutdriver or Flat Head Screw Driver
Electric Drill & 1/8 Diameter _
Drill Bit (5/32" Masonry Drill
Bit if installing in concrete)
Level & Measuring Tape
For gas supply connection:
Pipe Wrench i_
Brush
For burner flame adjustment:
Phillips head _ and blade-type _o
screwdrivers
For gas conversion (LP/Propane or Natural):
Open end wrench - 1/2" _
Additional materials you will need: _
Gas line shut-off valve
Pipe joint sealant that resists action of LP/_'---PfM_
Propane gas .............
A new flexible metal appliance conduit
(_,,_"NPT x 3/4" or _,,_" I.D.) must be design
certified by CSA International. Because
solid pipe restricts moving the range we
recommend using a new flexible conduit
(4 feet length) for each new installation
and additional reinstallations.
Always use the (2) new flare union
adapters _,'_" NPT x 3/4" or _,_" I.D.) supplied with the
new flexible appliance conduit for connection of the
range.
Cabinet Construction
_ To eliminate the risk of cabinet burns
and fire, do not have cabinet storage space above the
range. If there is cabinet storage space above range,
reduce risk by installing a range hood that projects
horizontally a minimum of 5" (12.7cm) beyond the
bottom of the cabinet.
| Cauntertop Preparation (figure 1)
° The cooktop sides of the range fit over the cutout
edge of your countertop.
° If you have a square finish [fiat) countertop, no
countertop preparation is required. Cooktop sides lay
directly on edge of countertop.
° Formed front-edged countertops must have molded
edge shaved fiat 3/4" (1.9 cm) from each front corner
of opening (Figure I).
° Tile countertops may need trim cut back 3/4"(1.9
cm) from each front corner and/or rounded edge
flattened [Figure 1).
3I_/2".._
(81 cm)
Formed or tile countertop trimmed
¾" (1.9 cm) back at front corners
of countertop opening.
Figure 1
If the existing cutout width is greater than
30-1/16" (76,4 cm), reduce the 3¼" (1.9 cm) dimension.
Countertop must be level. Place a level on the
countertop, first side to side, then front to back. If the
countertop is not level, the range wiii not be level.
The oven must be level for satisfactory baking results.
Cooktop sides of range fit over edges of countertop
opening.
Gas Entry Preparation
° The hatched areas are the locations where the gas
line can enter the cabinet [figure 2).
° The recommended position for the gas entry line is
located at 7" from the left cabinet wall and 2" from
the floor [figure 2).
° The shaded area is the location where the electric
outlet can be located [figure 2).
/
/
/
Recommended
position
\
Note: All dimensions are in inches (centimeter).
Figure 2
\ i
\
\
\
\
\
\
\\
\
',\
\
\
\
\
\
\