Installation guide

4. Attach 3%" x 10" Damper/Duct Connector over
knockout opening. Make sure damper Pivot is nearest
to W/Back Edge of hood. Remove any shipping tape
from damper flap.
3V4"x 10"
DAMPER/DUCT
CONNECTOR
PIVOT
5. Instal! Vent Cover over louvers at the front of hood. Insert
Tabs into top louvers, rotate cover downward, and snap
cover into bottom louvers.
VENT
COVER
/
TABS
6. Remove either top or back Wiring Knockout and instalI
approved Electricam Cabme Cream#,
WIRING
KNOCKOUT
ELECTRICAL
CABLE CLAMP