!iiiiii!ii_ili_: _! MODEL NO 661.623920 661.624420 661.624530 661.624630 661.624670 Kenmore CONV TIBLE DOWNIFRONT OUTLET EVAPORATIVE AmR COOLER AND o Installation o Operation e Repair Parts SEARS. 30780-6 ROEBUCK AND CO., Chicago. 1L 60684 U.S.A.
CONTENTS INSTALLATION Tools and Supplies You Need ................ 3 Safety Rules ............ Data ................................... Locating Your Converting to Side Mounting Electrical Final 3 3 ...................... Outlet ................... Check 5 and Adjustment 6 7 .......... 8 List ......................... 9 NEED ADVICE? MISSING ................... 10 Spring, Summer and Fall Care ............... Taking Off and Putting On Grills ............... Taking Off Pad .............
BNSTALLATgON TOOLS NEED AND SUPPLIES YOU WiLL e Duct, As Required (a local sheetmetal shopcan supply ducting) o Equipment Suitable for Installing Duct Through House Wal! or Roof o Water Connection, Use Kit # 62527, #62528 or #62522 Saddle Valve See page 8 (Connect Water line) for further information explaining the different water hook ups o Roof Stand Kit (if cooler is roof mounted) Cooler 66t ,623920 use 32-6256 kit Cooler 661 624420 use 32-6256 kit Cooler 661 624530 use 32-6257 kit o Cooler 661 62463
INSTALLATHON LOCATING YOUR COOLER Your cooler has been shipped ready for installation in a down discharge position.
aNSTALLATnON YOU MAY WANT TO CONVERT YOUR COOLER TO SIDE DISCHARGE (Figure 3) H.n CONVERTING DISCHARGE COOLER (F|G.4) TO SiDE AIR SIDE OUTLET ,_ DOWN OUTLET O Remove both louvers and set them where they will not fall See pg_ 11, "Taking Off Louver" Q Remove four motor grille clips on side opposite (_ Remove a reservoir by pushing the water crossover tube from the grommet and lifting out the reservoir,, (_) Remove the second reservoir as above.
INSTALLATRON LIFTING COOLER Lift at cabtnet corners CAUTION: DO NOT LIFT ON THE LOUVERS, REMOVE THE LOUVERS BEFORE LIFTING, DO NOT LIFT ON THE CENTER OF THE CABINET FLANGES MOUNTING COOLER The cooler may be Ilfted by putting a bar or strap through the panel hole and lifting by means of the beror strap (Fig 6) (Fig. 7) 1o Prepare duct to fit model used,, See outtet size specifications on page 3. 2. Cut opening in roof or wall to fit duct opening on cooler and box in opening= 3.
INSTALLATION ELECTRICAL CONNECTIONS Use only a Sears 32-6251 wall mounted switch.. This new cooler does not require prewetting the pads before starting cooling and does not have a pump Existing switches with "pump only" positlon are not usable. The wiring must comply with local code& If you are not familiar with the codes or wiring practices, get professional help.
iNSTALLATiON FINAL ASSEMBLY AND ADJUSTMENT COMPRESSION NUT PUT FLOAT VALVE IN COOLER Put the float valve through the spout hole and cabinet hole Tighten the ring nut Be sure the float moves straight up and down. TURN THE FLOAT UNTIL A NARROW SIDE IS UP.
IINSTALLATION MOTOR PULLEY ADJUSTMENT (Figure 13) NOTE: ALL DUCT CONNECTED COOLERS MUST BE ADJUSTED Long or small air ducts have excessive air resistance which decreases air output and motor amperage, You may compensate for this by adjusting the motor pulley.
HOW TO USE YOUR HOW YOUR COOLER COOLER WORKS Your cooler evaporates water to cool air.
CARE OF YOUR CAUTION: SPRING SUMMER ALWAYS UNPLUG YOUR COOLER BEFORE YOU WORK ON IT YOU COULD BE HURT IFTHE COOLER IS TURNED ON WHEN YOUR HANDS ARE tNS_DE THE COOLER CARE: CARE: FALL CARE: TAKING COOLER Clean your cooler (See page 12) Oil your cooler (See page 13) Put a new pad in if the old pad is plugged with dirt or water hardness, (See pages 12 and 13).
CARE OF YOUR COOLER TAKING OFF PAD (Fig. 19) 1. Lift up the small roller ends to unsnap the two center rollers Pull out the two small rollers 2. Pull out and turn the top roller bearing arm to line up the slot 3+ Lift edge of pad from under the guide and pull out the top roll end, 4, Take out the pad and bottom roller which will slide out of the bottom slots. CLEANING YOUR COOLER HELPS PREVENT MINERAL (FIG. 20) BUILD-UP 'WITH A GARDEN HOSE.
CARE OF YOUR PUTTING COOLER ON NEW PAD (Fig. 21) SEARS REPLACEMENT MODEL NUMBERSEARS _ 661.623920 661.624420 661.624530 661.624630 THE PADS NEED NO PREWETTING __. Put the lower roller in pad. Fit the lower roller into the botton slots in the frame ..... ._61.624670 PADS PAD NUMBER 42-6293 42-6293 42-6295 42-6295 Push the top roller through the pad, Fit the roll end over the pad motor shaft drive block _.
REPAUR PARTS KENMORE MODEL. CONVERTIBLE DOWN/FRONT NOS. 661.623920, OUTLET 661.624420, 47 ' EVAPORATIVE 661.624530, AIR COOLER. 661.624630, 661.624670 1 1:: 19 10 25 ( 23 4O 17 38 23 3O 35 34 25 28 48 50 49 _ 56 / 55 60_ 53 \ \ 56 55 54 14 26
REPAaR PARTS KENMORE CONVERTIBLE MODEL NOS. 661.623920, NOTICE: Order by PART NUMBER, KEY NO PART DOWN/FRONT 661.624420 not by Key Number NUMBERS FOR OUTLET EVAPORATIVE 661-624530,661.624630, Refer to the back cover of this manual MODEL NUMBERS 1 2 3 4 5 6 661.624420 30439 50255 STD523107 32-61073 30315 STD503102 66'1.624530 30439 50255 STD523107 32-61074 30315 STD503102 _ 661,624630 30439 50255 STD523107 32-61075 30315 STD503102 661.
KENtVtORE MODEL CONVERTIBLE 661,623920 44 501243 45 30433 47 30878 48 30214-01 49 31047 50 30206=01 51 30224-01 52 30211 53 30212 54 32-6293 55 30465 56 30233-01 57 V30336 58 29862 59 STD601103 " 30780-6 60 ! 30338 61 24971=1 62 523122 " 32-6256 " 32-62562 * 32-625! i * Unillustrated ** Included Model 661.624630 661.